2 - Manually manipulate the "C" fuel pump lever until the
all the air in the system has been eliminated through
the vent screws (fig.2 ref.5).
3 - Tighten the vent screws once more and start up the
engine.
4 - Repeat the above operations if the engine is still not
functioning properly.
INFORMATIONS
Consult the engine use and maintenance manual for
further details on the fuel system.

6.4 Cleaning and replacing the air filter

To ensure proper functioning and long engine life it is
important to clean and periodically replace the air filter
cartridge. An inefficient filter can cause loss of engine
power and can give rise to excessively smoky exhaust.
To replace the air filter cartridge operate as follows:
- Remove the lid from the air filter after having unhook the
securing jerky levers.(fig.4 rif.4).
- Remove the filter cartridge and insert a new on
positioning it carefully;
- Replace the lid and rehook it with the securing jerky
levers. (fig.4 rif.4).
- Rehook the hood with the securing jerky levers.
(fig.5 rif.1)
ATTENTION
Clean the air filter cartridge every 100 hours of opera-
tion.
Shorten this interval if the generator is operated in a
particularly dusty environment.
Replace the cartridge when it is excessively fouled or
damaged.

6.5 Cleaning the air intake grids

Periodically check the cooling air intake and discharge
grids (fig. 2 ref. 4-5) and the cylinder cooling fins for fouling.
These must be free of any foreign bodies which could
obstruct the flow of cooling air (i.e. leaves, paper, rags,
etc.).
6.6 Periods of inactivity
If the unit will not be used for a long period of time, the
following operations must be performed:
- replace the engine oil sump;
- replace the fuel filter;
- remove the injector, insert a few drops of oil inside the
combustion chamber and manually rotate the drive
shaft a few times; reinstall the injector and close the
suction and delivery openings.
GB

6.7 Table of scheduled operations

OPERATION
Check the level of the oil in the sump
Clean the air filter
Replace the oil sump
Check the level of the electrolytes
and thebattery charger status
Replace the fuel filter
Replace the oil filter
Regulate the play in the rocker lever
Calibrate and clean the injectors
Partial overhaul
General overhaul

6.8 Troubleshooting

The starter motor turns but the main engine does not
cut in.
- Make certain there is fuel in the tank (refill).
- Make certain that the Stop solenoid valve is powered
(contact the Service Center)
- Make certain that the fuel pump is functioning (contact
the Service Center)
The control panel does not cut in when the ignition
key is turned.
- Check the protection fuse (replace)
- Check the connection cable and electrical connectors
(reconnect)
- Make certain that the battery is operative (recharge or
replace)
The unit cuts out during operation.
- Check whether the protection has been activated and
the warning light is on (remove the cause and try to start
up again)
- Make certain there is fuel in the tank (refill)
The engine is running irregularly.
- Check the fuel filters (replace)
- Make certain that the fuel pump is operating properly
(replace)
- Check calibration of the injectors (contact an Author-
ized Service Center)