MODULE PROGRAMMING
Enter into programming mode as it's described on page 29.
Press arrow "DOWN" and "V"buttons simultaneously
V
Press arrow "UP" button till the desired first digit appears
Press arrow "DOWN" button to move to the next digit.
Press arrow "UP" button till the desired 2nd digit appears
Press arrow "DOWN" button to move to the next digit.
Press arrow "UP" button till the desired 3rd digit appears
To validate the code, press "V" button during 2 seconds:
V
P
rogramming code modification.
during 7 seconds: the left display will shows number 0.
on the display.
The left display will turn off and the center display
will show number 0.
on the display.
The center display will turn off and the right display
will show number 0.
on the display.
the display will show the complete code and
will automatically exit from the programming mode.
31
32
T
ime activation modification.
Enter into programming mode as it's described on page 29.
V
IMPORTANT: a varistor and a diode are supplied with this proximity reader.
In case to connect an a.c. lock release, place the varistor on the lock release
terminals directly.
In case to connect an d.c. lock release, place the diode on the lock release
terminals directly. Special attention on polarity is required.
a.c. lock release
MODULE PROGRAMMING
Press arrow "UP" and arrow "DOWN" buttons
simultaneously, till the display shows the existing
activation time with "-" character.
Time is shown in seconds.
Press arrow "UP" button to increase or arrow "DOWN"
button to decrease the activation time, till obtain
the desired value.
To validate the new activation time, press "V" button
during 2 seconds: the display will show the new value
and will return to the programming mode.
LOCK RELEASE INSTALLATION
R
eader module protection.
d.c. lock release
-
+