46
ENGINE OPERATION
ENON00504-0
Note
The free accel lever can not be raised when
the control lever shift is in Forward or
Reverse.
3
1. Neutral (N)
2. Control lever
3. Fully opened (Forward)
4. Fully opened (Reverse)
5. Free throttle lever
7
6. Main switch key
7. Stop switch
5. Turns the main switch key to START
position. Then, continuously push the
key to operate the choke.
ENON00503-0
Note
Choke operation is not necessary if the
engine is warm.
6. Stop pushing the key when the engine
has started.
The key returns to the original position,
automatically.
7. Returns the Free accel lever to close
position.
8. Check the cooling water from cooling
water check port.
1
2
N
5
4
6
7
ENOF00870 1
ENON00035-A
Note
The free throttle lever can not be raised
when the control lever shift is in Forward or
Reverse.
2
1. Cooling water check port
2. Idle port
ENOM00042-A
Emergency starting
ENOW00099-A
WARNING
When the emergency starter rope is used
for starting engine;
Start in gear protection does not work.
Be sure to shift is at neutral position.
Otherwise the engine will move the boat
immediately and cause personal injury.
Be careful that your clothes or other
items do not get caught in the rotating
engine parts.
To prevent accident and injury by rotat-
ing parts, do not re-attach flywheel
cover and the top cowl after the engine
has been started.
Do not pull starter rope if any bystander
is behind. The action can injure the
bystander.
Attach engine stop switch lanyard to
clothing or any part of body like arm
before starting engine.
1
ENOF01911-0