NO USER SERVICEABLE PARTS
WARNING
INSIDE. Preventive maintenance
performed by un au thorized personnel may result in
misplacing of internal wires and components which
could cause serious hazard. We recom mend that all
tool service be performed by a Dremel Service Facility.
SERVICE MEN: Disconnect tool and/or charger from
power source before servicing.
D.C. motors
The motor in your tool has been engineered for many
hours of dependable service. To maintain peak efficien-
cy of the motor, we recommend it be examined every
six months. Only a genuine Dremel replacement motor
specially designed for your tool should be used.
To avoid accidents, always dis-
WARNING
connect the tool and/or charger
from the power supply before cleaning. The tool may
be cleaned most effectively with com pressed dry air.
Always wear safety goggles when cleaning tools with
compressed air.
Certain cleaning agents and sol-
CAUTION
vents damage plastic parts. Some
of these are: gasoline, car bon tetrachloride, chlorinated
cleaning solvents, ammonia and household detergents
that contain ammonia.
Service
Cleaning
Maintenance
WARNING
tors that is capable of carrying the current necessary
for your tool must be used. This will prevent excessive
voltage drop, loss of power or overheating. Grounded
tools must use 3-wire extension cords that have 3-
prong plugs and receptacles.
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Tool's
Ampere
Rating
3-6
6-8
8-10
10-12
12-16
NOTE: The smaller the gauge number, the heav i er the
cord.
17
Extension Cords
If an extension cord is necessary,
a cord with adequate size conduc-
Cord Size in A.W.G.
Cord Length in Feet
Cord Length in Meters
25
50
100 150
18
16
16
14
18
16
14
12
18
16
14
12
16
16
14
12
14
12
—
—
Wire Sizes in mm 2
15
30
60
120
.75 .75 1.5
2.5
.75 1.0 2.5
4.0
.75 1.0 2.5
4.0
1.0 2.5 4.0
—
—
—
—
—