AVENTICS | AS3-SV | R412026750–BAL–001–AD | English
Safety classification
Directives
Standards
Test principle
Safety functions
Vibration resistance (DIN EN 60068-2-6)
Shock resistance (DIN EN 60068-2-27)
Safety classification
Mean time to dangerous failure
Common Cause Failure – CCF
Diagnostic coverage (DC)
Maximum number of cycles
Monitoring
Noise level [dB (A)]
Minimum operating frequency
O
For further technical data, see the catalog pages in the AVENTICS online catalog
(see www.aventics.com/pneumatics-catalog).
2006/42/EC (Machinery Directive)
2004/108/EC (EMC directive)
ISO 13849-1, IEC61508/IEC62061,
DIN EN 61326-3-1
GS-IFA-M07, April 2017
"Safe exhaust" and "protection against
unexpected start-up"
0.35 mm ± 0.05 mm displacement at
10 Hz–55 Hz
30 g with 18 ms duration
Shock wave form: Sinus half-wave
Max. category 4, PL e, SIL 3
See B
from the AVENTICS SISTEMA library
10D
> 65
High, 99%
2/s, measured without volume
The switching frequency reduces depending
on the volumes to be filled.
Dynamic, cyclic, internal
Monitoring of the control state of sensors with
all state changes of valve control signals.
The sound pressure level is influenced by the
individual systems to reduce noise emissions.
Exhausting of the valve may not be restricted.
We do not recommend using the product
without silencers.
Once per month to guarantee perfect working
order.
14