OPERATING ACCESSORY TOOLS (OPTIONAL)
1. Attach accessory solution hose to quick coupler.
2. Disconnect squeegee hose from inlet tube and
replace with accessory vacuum hose.
3. Connect hoses to wand.
4. Plug power cord into a grounded wall outlet
(Figure 21).
Grounded Outlet
Grounding
Edge/hole
(220V/230V/240V)
FIG. 21
FOR SAFETY: Do not operate machine unless
cord is properly grounded.
5. Turn on main power, wand pump and vacuum
switches (Figure 22).
FIG. 22
6. Operate tool as normal.
WARNING: Do Not Pick Up Flammable
Materials Or Reactive Metals.
Tennant 5100 (05- -05)
Home
Find... Go To..
CIRCUIT BREAKER
The model is equipped with a circuit breaker to protect
brush motor from damage.
Brush motor circuit breaker will trip due to excessive
overload on pad. Reduce pad pressure or replace pad
if breaker trips. Circuit breaker is located on control
console (Figure 23).
If circuit breaker should trip, the breakers will not reset
immediately upon tripping. Determine reason why
breaker tripped, wait a few minutes and reset (See
TROUBLE SHOOTING).
FIG. 23
MACHINE ADJUSTMENTS
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off machine
and unplug cord from wall outlet.
ADJUSTING SOLUTION FLOW
To increase or decrease the maximum solution flow,
turn adjustment knob. Adjustment knob is located near
brush lift pedal (Figure 24).
FIG. 24
OPERATION
11