Making Electrical Supply
Connections (L-40)
1. Route the heater's electrical connections through the
water tight connector as shown. See Fig. 14.
2. Using a wire nut, connect the 24 VAC incoming
power to the factory supplied lead at the on/off
switch.
3. Connect customer supplied neutral and ground to
factory supplied neutral and ground leads.
4. Install control box cover, using qty. 2 screws, item C.
FIG. 14
Factory supplied
neutral and ground
leads
Customer supplied
wiring routed
through water
tight connector.
(24 VAC power /
neutral / ground)
Owner's Manual • L-40 / H-40
24 VAC power lead
Power supply neutral and
ground (Connected to
factory supplied neutral
and ground leads)
Making Electrical Supply
Connections (H-40)
Plug the heater's power cord into a properly grounded
120 VAC electrical supply.
Ignition cable
Factory supplied lead
(ON/OFF switch to ignition
control)
Factory supplied lead
(connect to 24 VAC power