L-40 / H-40 Spark Ignition Radiant Brooder
Specifications
Model Number:
Input (Btuh)
Ventilation Air to Support Combustion
Inlet Gas Supply Pressure Required
at the Heater
Burner Manifold Pressure
Heater Dimensions (See Fig. 1)
Net Weight
Fuel Consumption Per Hour
Electrical Supply (Volts/HZ/Phase)
Amp Draw
Recommended Height Installation
From Edge of Canopy to Floor
Minimum Safe Clearances to
Combustible Materials
FIG. 1
Owner's Manual • L-40 / H-40
LP GAS MAX.
LP GAS MIN.
NATURAL GAS MAX.
NATURAL GAS MIN.
LP
NG
"A"
"B"
"C"
LP GAS
NATURAL GAS
Top of Canopy to Ceiling
Edge of Canopy to Floor
All Sides
"B"
"A"
L-40
H-40
40,000
468 CFM
13.5 in.W.C.
11.0 in.W.C.
5 PSIG
13.5 in.W.C.
7.0 in.W.C.
10.0 in.W.C.
5 PSIG
4.0 in.W.C.
30 3/4 in.
20 1/4 in.
18 in.
16 lbs.
1.85 lbs. / hr.
40 CFH
24 / 60 / 1
120 / 60 / 1
0.5
5 - 6 ft.
17 in.
55 in.
36 in.
"C"