5- Description of the LEDS in the circuit:
Abbreviation
AC
Shows whether there is mains power (lit if there is mains voltage)
STPA
Displays the status of the STPA input (terminal 16), if not engaged the green LED remains lit, if not used then jumper between
terminal COM and STPA
AP/CH
Displays the status of the AP/CH input (terminal 11), if not engaged the red LED remains off
APED
Displays the status of the APED input (terminal 12), if not engaged the red LED remains off
STOP
Displays the status of the STOP input (terminal 14), if not engaged the green LED remains lit, if not used then jumper between
terminal COM and STOP
PHOTO
Displays the status of the photo input (terminal 15), if not engaged the green LED remains lit, if not used then jumper between
terminal com and photo.
FCAP
Displays the status of the opening limit switch with parameter 31 off, the green LED goes out when the gate is fully open. Displays
the status of the closing limit switch with parameter 31 on, the green LED goes out when the gate is fully closed.
FCCH
Displays the status of the closing limit switch with parameter 31 off, the green LED goes out when the gate is fully closed. Displays
the status of the opening limit switch with parameter 31 on, the green LED goes out when the gate is fully open.
ENC.A
Displays the encoder A input, on steady when the motor is moving at cyclical speed, flashing during slowdown, off with the motor
stopped.
ENC.B
Displays the encoder B input, on steady when the motor is moving at cyclical speed, flashing during slowdown, off with the motor
stopped.
PROGRAM MENU
Displays the programming menu
DISPLAY
Buttons in the circuit:
Abbreviation
AP/CH
ESC
UP
DOWN
ENTER
Preliminary check:
After powering up the control panel, the display shows the name of the control panel RS06, the firmware version Fxxx and 3 flashes with the words FLSH
and then switches off. Check the LEDs for diagnosis of the inputs, the STOP, PHOTO. , STPA, FCAP and FCCH LEDs must be on (if the limit switches are
not engaged).
Should one of the safety inputs (PHOTO. , STOP, STPA) not be used, insert a jumper between COM and the input not used.
6- Quick programming
Procedure for facilitated gate travel programming:
N.B.: Before you start programming, check parameter 31 (opening direction)
OPENING
APERTURA
EN
Description
Controls opening and closing the gate
Exit or go back to the lower level of the menu
Increases the displayed value by one unit or scrolling on the same menu level
Decreases the displayed value by one unit or scrolling on the same menu level
Confirms the value or moves to the top level of the menu, when pressed while the
gate is moving it shows the absorption of the electric motor in Amps
OPENING
APERTURA
Description
Parameter 31 ON
Parameter 31 OFF
31
31