N.B.: The first saved remote control configures the control panel to accept only remote controls with a rolling code or only remote controls with
a fixed 12-bit code
If you need to delete all the remote controls, enter the RAD menu, select ALL (between number 001 and 200), press and hold the OK button for 5
at least seconds, and the display will show the 4 dots confirming the operation.
It is advisable to fill in the final table indicating the number of the memory cell (it is displayed while saving the remote control) in the user name,
this enables deleting a remote control should it get lost.
7.3 LRN:
Learning travel with custom programming lets you define the points for starting deceleration when both opening and closing:
-
move the gate into the fully closed position (closing limit switch engaged, SW.CL LED off)
-
press the OK button to enter programming mode, the display will read APCH
-
press and release the AP/CH button, the gate will open and the display will show OPEN
-
press and release the AP/CH button to determine the starting point of deceleration on opening and the display will show the message SLO
-
the gate continues slowing down until the opening limit switch trips (the SW.OP LED goes out) and then automatically starts closing again, the display
shows the message CLOS
-
press and release the AP/CH button to determine the starting point of deceleration on closing and the display will show the message SLO
-
the gate continues slowing down until the closing limit switch trips (the SW.CL LED goes out)
-
the gate opens and the display shows OPEN
-
press and release the AP/CH button to determine the pedestrian opening distance
-
the gate continues until the closing limit switch trips (the SW.CL LED goes out) the display reads END, the travel has been saved correctly.
36
36
CLOSING
EN