TDK-Lambda CUS100ME Manual De Instrucciones página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 9
CUS100ME Handbook
Input Parameters
Parameter
Nominal input voltage
Input voltage range
Input frequency range
Maximum input current
* For operation at 440Hz, please contact Technical Sales.
Output Parameters
Output power is reduced linearly by 10% for input voltages from 89.99 to 85Vac.
There are seven CUS100ME standard models as shown in the tables below. All of these models may
be forced air, conduction, or convection cooled. The output parameters are shown in the tables below.
Outputs are not user adjustable but can be factory set.
Output Parameters Table
CUS100M
Model
12
15
18
24
28
36
48
Variation and Limitations:
Customer Forced Air Cooling max ambient 85°C (note 1)
Convection and conduction/cold plate cooling (U chassis with lid-Option A) max ambient 75°C (note 1)
Convection and conduction/cold plate Cooling (U chassis and open frame) max ambient 80°C (note 1)
Note1. Maximum output power and current ratings are dependent on the ambient used in the end equipment.
Please see power curves for guidance
60601-1
100 - 240 Vac
85 - 264Vac
47 - 63Hz
1.4A rms
Vout
Range (V)
12-13.2
15-16.5
18-19.8
24-26.4
28-30.8
36-39.6
48-50
Page 16 of 24
60950-1& 62368-1
100 - 240 Vac
85 - 264Vac
47 - 63Hz*
1.4A rms
Max
Iout (A)
8.33
6.66
5.55
4.16
3.57
2.77
2.08
Max
Pout (W)
100
100
100
100
100
100
100
260423-3 Mar 2019

Publicidad

Tabla de contenido
loading

Tabla de contenido