TDK-Lambda CUS100ME Manual De Instrucciones página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 9
CUS100ME Handbook
Variations and limitations of use:
1. Component temperatures, for customer air, Conduction, or convection cooled models, must be monitored
in the end use application as described in the " Cooling for Unit Temperature Table" below .
Cooling for unit
The following method must be used for determining the safe operation of PSUs.
The components listed in the following table must not exceed the temperatures given. To determine the
component temperatures the heating tests must be conducted in accordance with the requirements of the
standard in question. Consideration should also be given to the requirements of other safety standards.
Test requirements include: PSU to be fitted in its end-use equipment and operated under the most adverse
conditions permitted in the end-use equipment handbook/specification and which will result in the highest
temperatures in the PSU. To determine the most adverse conditions consideration should be given to the
end use equipment maximum operating ambient, the PSU loading and input voltage, ventilation, end use
equipment orientation, the position of doors & covers, etc. Temperatures should be monitored using type K
fine wire thermocouples (secured with cyanoacrylate adhesive or similar) placed on the hottest part of the
component (out of any direct airflow) and the equipment should be run until all temperatures have stabilised.
Cooling for Unit Temperature Table:
Circuit Ref.
L1
L2
L3
C1
C2
C104, C105
C6, C102
C3
C5, C100, C101, C103,
TX100
XU101, XU102
XD8
J1
J100
Higher temperature limits (in brackets) may be used but product life may be reduced.
Description
Common Mode Choke
PFC choke
Differential mode choke
Film capacitor
Electrolytic Capacitors
Electrolytic Capacitors
Electrolytic Capacitors
X Capacitor
Y Capacitors
Transformer Winding
Opto-Coupler
Diode
Input Connector
Output Connector
Page 18 of 24
Max. Temperature
(°C)
110 (130)
125 (130)
125 (130)
105
90 (105)
92 (105)
93 (105)
100
105
110
100 (110)
130
105
105
260423-3 Mar 2019

Publicidad

Tabla de contenido
loading

Tabla de contenido