HOT EXHAUST
ALARM
ACTIVATD

SAFETY DEVICES

- The appliance is equipped with different security features, which grant and assure the
regular functioning.
-Pressure switch for the control of exhaust fumes. In case of obstruction of the fume
exhaust duct, due to materials, contrary wind, or to any other difficulty that do not allow a
regular outflow of the fumes, this device signals the problem to the appliance and a stop
cycle starts, while on the display appears "FAILURE DEPRESS"and a beep will sound.
-Fume temperature control. The temperature of the exhaust fumes is constantly controlled
by a specific feeler in order to control the regular working of the appliance, in case the
temperature is exceeding the max. value (factory value setting) a cooling cycle starts,
reducing the power (HOT EXHAUST), if the temperature of the fume is still increasing a stop
cycle starts, while on the display appears "HOT EXHAUST" and a beep will sound.
-Exhaust fumes motor control. The electric motor for exhaust fumes is continuously
checked in order to verify the correct functioning and in case of anomaly, a stop cycle will
start and the display will signal "FAN LIGHTIN" and a beep will sound.
-Control of temperatures feelers. The correct working of the feelers, which ensure a correct
working of the appliance, are constantly controlled by the electronic card. If the controlled
values do not re-enter into the working parameters a stop cycle starts, while on the display
appears a message of alarm.
SAFETY
Easy to use, safety of operation. The digital control panel controls the combined action
of the gas combustion fan, of the fuel loading, of the convection fan and of the control of
the room temperature. This control system grants the best combustion and functioning
conditions, reducing to the minimum the costs of functioning.
Maximum efficiency, minimum emissions. The large heat exchange surface, together
with an optimal control of the combustion air, provides an excellent yield of the fuel.
The release of the pellets dosed in the brazier, allows a complete combustion with low
emissions in the exhaust gas.

AUTOMATIC SAFETY FEATURES

Voltage drop. Even after a brief voltage drop, the unit stops and then restarts,
resuming the normal operation or restarting the automatic ignition phase,
without any security risk.
Low-temperature shutdown. If the temperature of the appliance drops down to a certain
value, the unit turns off (for example the finishing of the fuel). This can also be switch
off can also accur if the lighting phase takes to much time. The stove must then be re
switched on again The persistence of this condition must be verified by the service center
or qualified personnel.
Fumes temperature
too high
Appliance in Alarm,
start of stopping
cycle
The appliance has detected a fumes temperature too
high, the power reduces automatically.
Appliance noticed an anomaly, extinction cycle starts
and the display signals the type of problem.