Preliminary Checks - BFT VIRGO Instrucciones De Uso

Ocultar thumbs Ver también para VIRGO:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
ENGLISH
Thank you for buying this product. Our company is sure that you will be
more than satisfied with the product's performance.
Carefully read the "WARNINGS" pamphlet and the "INSTRUCTION
BOOKLET" which are supplied together with this product, since they
provide important information regarding the safety, installation, use and
maintenance of the product. This product complies with recognised technical
standards and safety regulations. We declare that this product is in
conformity with the following European Directives: 73/23/ EEC, 89/336/
EEC, 98/37/EEC and subsequent amendments.
1) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the
following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and
subsequent amendments. As for all non-EEC countries, the above-
mentioned standards as well as the current national standards should
be respected in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and
subsequent amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying
and shearing, according to and in compliance with the applicable
directives and technical standards.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components are
used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation
area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
2) GENERAL OUTLINE
Low-voltage operator (24Vdc) suitable for residential use. Designed for
swing gates having small-sized pillars. The operating arm, with its special
antishearing shape, allows the leaves to be manoeuvred even when the
operator is positioned well away from their fulcrum. The irreversible
electromechanical gearmotor keeps the gate locked in the closing and
opening positions.
The release lever, fitted to the outside of each operator, allows the manual
16 -
VIRGO Ver. 03
INSTALLATION MANUAL
manoeuvre to be carried out very easily.
WARNING! The installation, the maintenance and the repair should be
done by responsible and qualified persons with an updated knowledge of
the current safety standards. It's strictly forbidden to service the automation
when the power is on.
ATTENTION! The VIRGO model controller is not equipped with mechanical
torque adjustment. It is compulsory to use a control panel of the same
manufacturer, in compliance with the basic safety requirements of directives
73/23/CEE, 89/336/CEE, 98/37/CEE equipped with appropriate electric
adjusment of the torque.
3) TECHNICAL SPECIFICATIONS
3.1) VIRGO OPERATOR
Motor: ............................................................................ 24Vd.c. 2500 min
Power: .................................................................................................. 40W
Insulation class: ........................................................................................ F
Lubrication: ................................................................... Permanent grease
Reduction ratio: ............................................................................... 1-1224
Output shaft revolutions: ......................................................... 2 min
Opening time 90°: ................................................................................. 14s
Torque supplied: ............................................................................ 170 Nm
Max leaf weight and length: .................. 2000N (~200kg) for 2m long leaf
Impact reaction: ................................................... Integrated torque limiter
................................................................................. on LINX control panel
Motion drive: ............................................................................... Lever arm
Stop: ................. Incorporated electrical limit switches + mechanical locks
Manual manoeuvre: ....................................... Release lever with CLS key
Number of manoeuvres in 24h: .............................................................. 60
Environmental conditions: ............................................ from -15 to +60 °C
Degree of protection: ......................................................................... IP 44
Operator weight: ................. VIRGO:80N (~8kg) - VIRGO SQ:60N (~6kg)
Dimensions: .................................................................................. see fig.1
3.2) LINX CONTROL PANEL
Power supply: ......................................................... 230Va.c. ±10% 50Hz*
Mains/low voltage insulation: ....................................... > 2MOhm 500Vdc
Working temperature ............................................................. : -10 / +55°C
Dielectric strength: ................................ mains/l.v. 3750Va.c. for 1 minute
Motor output current: ......................................................... 3.5A+3.5A max
Motor relay commutation current: ........................................................ 10A
Maximum motor power: ....................................................... 40W (24Vd.c.)
Power supply for accessories: ............. 24Va.c. (180mA max absorption)
....................................................... 24Va.c.safe (180mA max absorption)
Gate-open warning light: .......................... N.O. contact (24Va.c./1A max)
Blinker: ........................................................................... 24Va.c. 25W max
Dimensions: ............................................................................. see figure 1
Fuses: ...................................................................................... see figure 2
(*other voltages available on request)
3.3) VIRGO BAT BATTERY KIT (OPTIONAL - Fig.14)
Allows operation to continue even when the mains power supply is off for
a short time.
Charge voltage: ........................................................................... 27.2Vd.c.
Charge current: ............................................................................... 130mA
Data detected with external temperature of: ...................................... 25°C
Battery capacity: ................................................................. 2x (12V 1.2Ah)
Exhausted battery protection threshold: ..................................... 20.4Vd.c.
Battery recharge time: .................................................................... 12/14 h
NOTE: In case of operation with battery back up, the outputs to terminals
8-9 (Vsafe 24Va.c.) and 10-11 (Vsafe 24Va.c.) show a voltage of 24Vd.c.
polarised as indicated in Fig.13.
At the time of installing the VIRGO BAT Kit, check that the safety devices
are connected correctly.
4) OPERATOR INSTALLATION

4.1) Preliminary checks

Check that:
The gate structure is sufficiently sturdy and rigid.
The fixing position must be worked out according to the leaf structure. In
any case, the manoeuvring arm must push against a reinforced leaf
point (fig. 2).
The leaves can be moved manually along their entire stroke.
If the gate has not been installed recently, check the wear condition of all
its components. Repair or replace defective and worn parts.
Operator reliability and safety are directly affected by the condition of
the gate structure.
-1
-1
MAX

Publicidad

Tabla de contenido
loading

Tabla de contenido