General Outline; General Safety; Technical Data; Preliminary Checks - BFT URANO BT Instrucciones De Uso Y De Instalacion

Servomotor para cancelas correderas de cremallera
Ocultar thumbs Ver también para URANO BT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39
ENGLISH
Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with
a "Warnings" leaflet and an "Instruction booklet". These should both be
read carefully as they provide important information about safety, installa-
tion, operation and maintenance. This product complies with the recognised
technical standards and safety regulations. We declare that this product
is in conformity with the following European Directives: 89/336/EEC and
73/23/EEC (and subsequent amendments).

1) GENERAL OUTLINE

The URANO BT actuator offers ample installation versatility, thanks to the
extremely low position of the pinion, the compactness of the actuator and to
the height and depth which can be very easily adjusted. It is equipped with an
antisquash electronic device, which ensures utmost safety. The emergency
manual release can be activated very easily by means of a knob featuring
a personalised key.
The gate stop is controlled by electromechanical end-of-stroke microswitches
or, for very cold areas, by proximity sensors.
The control board can be built-in or installed onto a separate cabinet.
The gearmotor (fig. 1) is made up of the following:
M
Motor
R
Worm screw - worm wheel reduction gear
S
Electromechanical end-of-stroke unit or proximity sensor
P
Pinion with release
C
Control board
B
2 buffer batteries (BT BAT 2)

2) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product can
cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC and subsequent amend-
ments. As for all non-EEC countries, the above-mentioned standards as
well as the current national standards should be respected in order to
achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe GoodTechnical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
The installation must comply with the provisions set out by the following
European Directives:89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fitallthesafetydevices(photocells,electricedgesetc.)whichareneededtoprotect
the area from any danger caused by squashing, conveying and shearing.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation safety
and correct operation when other manufacturers' components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
16 -
URANO BT Ver. 04
INSTALLATION MANUAL
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.

3) TECHNICAL DATA

Power supply: ........................................ single-phase 230V ±10% 50Hz (*)
Motor: ................................................................................................ 24Vdc
Absorbed power: .................................................................................. 80W
Insulation class: ......................................................................................... F
Reduction ratio: .................................................................................... 1/50
Output revolutions:........................................................................... 39min
Pinion pitch: ......................................................................... 4mm (18 teeth)
Leaf speed:........................................9m/mm(18 teeth) 12m/min (25 teeth)
Max. capacity:.................................... with pinion Z18 12.000 N (≈1200 kg)
Type of end-of-stroke limiting device:........... electromechanical or inductive
Buffer batteries (optional): ........................................ 2 batteries 12V 1.2Ah
Max torque:........................................................................................ 30Nm
Impact reaction: ..................................................... Electronic torque limiter
Lubrication:.................................................................... Permanent grease
Manual manoeuvre:............................................. Mechanical knob release
Manoeuvres in 24 hours: ...................................................... intensive cycle
Control unit: ..................................................................................... QSC D
Environmental conditions:........................................... from -15°C to +60°C
Degree of protection: ........................................................................... IP24
Dimensions:.................................................................................. See fig.2
Actuator weight:...................................................................200N (
Max leaf weight: .........................................................12.000N (
(*) Special supply voltages on request.
3.2) QSC-D Control unit technical data (Fig.17)
Supply to accessories:....................................................... 24Vac (180 mA)
Ampere-stop setting: ............................................. on closing and opening
Automatic closing time: ........................................................ from
Working time:...................................................................................... 2 min
Pedestrian opening time:................................................................ 7s fixed
Reverse pause:........................................................................... approx. 1s
Blinker connection: ............................................................... 24V max 25W
Fuses:......................................................................................... See fig.17
Parameter and option setting:....................... by means of keys or UNIPRO
Incorporated Rolling-Code radio receiver:............... frequency 433.92MHz
Coded by means of :.............................................. Rolling-Code Algorithm
No. combinations: .......................................................................... 4 milliard
Antenna impedance: ...........................................................50Ohm (RG58)
Max no. radio controls to be memorised:................................................. 64
3.3)
Transmitter versions which can be used:
all Rolling Code transmitters compatible with

4) PRELIMINARY CHECKS

Before proceeding to any installation work, check that the gate structure
conforms to whatever is prescribed by the current standards, and in
particular that:
• The gate sliding track is linear and horizontal, and the wheels are suitable
for supporting the gate weight.
• The gate manual operation can be carried out smoothly along its entire
run, and there is no excessive side slipping.
• A correct play is provided between the upper guide and the gate to ensure
regular noiseless movement.
• The opening and closing gate stops are positioned.
• The established position for gearmotor fixing allows the emergency ele-
ments checked do not meet the above requirements, proceed to carrying
out the necessary corrective actions or replacements.
WARNING:Remember that control devices are intended to facilitate gate
operation, but can not solve problems due to any defects or deficiency
resulting from failure to carry out correct installation or maintenance.
Take the product out of its packing and inspect it for damage. Should it be
damaged, contact your dealer.Remember to dispose of its components (card-
board, polystyrene, nylon, etc.) according to the current prescriptions.
5) BASE PLATE ANCHORING
5.1) Standard position
• Dig a hole where the cement pad with the buried base plate log bolts is to
be placed in order to fix the reduction gear unit (fig.3). If the sliding track
is already there, digging must be partly carried out in the track foundation
casting. This way, should the track foundation casting sag, the gearmotor
base would also lower, thus maintaining the play between pinion and rack
(approximately 1-2 mm).
• Position the base plate according to the dimensions specified in fig.4.
• The pinion symbol printed on the base plate must be visible and directed
towards the gate.This also ensures the correct positioning of the raceways
for electrical connections.
• Let the flexible pipes containing electrical cables protrude from the
base plate.
with pinion Z25 6.000 N (≈600 kg)
20 kg)
1200 kg)
3
to 120s
.
-1

Publicidad

Tabla de contenido
loading

Tabla de contenido