PROGRAMMING AND STARTUP KM1800
SW2 functions
Functions during programming (DIP1=ON)
DIP2=ON: total open/close programming (see
page 72)
DIP3=ON: pedestrian open/close programming (see
page 73)
DIP4=ON: total opening radio code programming (see
page 71)
DIP6=ON: pedestrian opening radio code
programming (see page 71)
70
Installation Guide
Functions during use (DIP1=OFF)
DIP2: advance warning
DIP2=ON: the flashing light comes on and the
operation begins after a 3 second warning.
DIP2=OFF: the flashing light comes on and the
operation begins immediately.
DIP3: step-by-step or collective opening
DIP3=ON: step-by-step opening (the panel obeys
the key commands during opening).
DIP3=OFF: collective opening (the panel does
not obey the key commands during opening).
DIP4: automatic or step-by-step closing mode (in
total and pedestrian operation)
DIP4=ON: automatic mode (the gate closes
automatically after the standby time has passed,
which is adjusted using T.E.).
DIP4=OFF: step-by-step mode (the gate only
closes when receiving the key command).
DIP5: automatic mode optional (only if DIP4=ON)
DIP5=ON: during standby, the gate obeys the
key commands (this can be closed before standby
time finishes).
DIP5=OFF: the gate cannot be closed until
standby time finishes.
DIP6: opening photocell testing
DIP6=ON: testing enabled
DIP6=OFF: testing disabled
DIP7: always place in OFF
DIP8: always place in OFF
DIP9: closing photocell testing
DIP9=ON: testing enabled
DIP9=OFF: testing disabled
DIP10: always place in OFF