RECORDING IMAGES IN THE ALARM
RECORDING AREA
Pre-alarm recording
Setting the time
1
Press the MENU button to display the LANGUAGE/CLOCK SET menu, and set
the date and time. After the setting has been made, press the EXIT/OSD button,
MENU
the date and time appear in the operating display. (See page 42.)
Set pre-alarm recording.
2
Press the MENU button to display the ALARM REC MODE SET menu. Set
ALARM RECORDING to the desired alarm recording setting (example: MODE1).
REC/STOP
The *** setting for PRE-ALARM RECORDING will be set to "OFF", so change it
to "ON". (See page 56.)
Press the EXIT/OSD button to return to the normal screen. "PRE" appears in the
operating display, the ALARM indicator illuminates and pre-alarm recording
starts (the a mark does not appear).
The same monitored image as in the normal recording area is recorded
repeatedly in the alarm recording area.
Recording onto the hard disk proceeds automatically (default setting) according
ALARM
to the following settings. The settings can be changed between long-period
recording and high-quality recording in five steps. (See page 49.)
•
•
•
•
When an alarm is received, pre-alarm recording stops
3
automatically and the alarm images are recorded.
The "PRE" disappears from the operating display, "ALARM" flashes and the
ALARM indicator flashes.
ALARM
Note:
•
•
Hard disk recording areas:
Normal recording area: 80%
Alarm recording area: 19%
Archive area: 1%
Picture quality: EN (Enhanced)
Recording method: Field
Recording speed: 0.10 seconds (54H)
When the remaining area in the alarm recording area reaches 1%, the
ALARM FULL indicator on the front panel flashes. If recording is continued
under these conditions, the recording area is filled and the recording stops.
In the RECORDING AREA SET settings, carry out the AREA FULL RESET
operation for the normal recording area.
Recording will then be possible from the beginning again. (See page 48.)
Refer to the recording speed tables for details on the pre-alarm recording
speeds. (See page 12.)
Pre-alarm images
are recorded
18
Monitored images
are recorded
<MAIN MENU 1>
1.LANGUAGE/CLOCK SET
->
2.VIDEO INPUT SET
->
3.RECORDING AREA SET
->
4.RECORDING CONDITIONS SET ->
<LANGUAGE/LANGUE/IDIOMA>
ENGLISH
<CLOCK SET>
01-01-2001 MON
00:00:00
S
S
<ALARM REC MODE SET>
PICTURE QUALITY
: ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING
: OFF
ALARM RECORDING
: MODE1
REC CYCLE : 0.10SEC.
DURATION: 1SEC
PRE-ALARM RECORDING
: ¤¤¤
REC CYCLE : ¤¤¤ SEC.
DURATION: ¤¤¤
=> (46400 ALARMS CAN BE RECORDED)
ALARM TRIGGER
: ALARM
MOTION SENSOR
->
10-05-01 PRE
0000
18:10:25 EN 0.10SEC
10-06-01 ALARM 0000
09:30:15 EN 0.10SEC
POWER
FULL
ALARM FULL
LOC
English