ALARM REC MODE SET SETTING
Alarm trigger setting
1
Use the jog dial to move the cursor to the ALARM TRIGGER
setting.
2
Turn the shuttle dial clockwise, use the jog dial to select the
method of detecting suspicious people (example:
" SENSOR" ), and then turn the shuttle dial.
The cursor moves to MOTION SENSOR.
Display examples: Alarm recording trigger settings
•
ALARM: Alarm recording is carried out when an external
alarm (when a switch is connected to the ALARM IN terminals
at the rear of the unit for open/close operation occurs).
•
SENSOR: Alarm recording is only carried out when the motion
sensor detects a moving object. Refer to motion sensor
settings.
•
ALARM AND SENSOR: Alarm recording is carried out when
there is a response from both an external alarm and a built-in
motion sensor.
•
ALARM OR SENSOR: Alarm recording is carried out when
there is a response from either an external alarm or a built-in
motion sensor.
Note:
•
MOTION SENSOR settings must be made if SENSOR, ALARM
AND SENSOR or ALARM OR SENSOR is selected.
•
The digital video recorder's built-in motion sensor cannot be used if
a multiplexer is connected to the digital video recorder.
•
If using the built-in sensor of a multiplexer, the alarm output should
be directed to the alarm input of the digital video recorder in order
to record alarms.
•
If you stop recording while alarm recording that has been triggered
by a motion sensor is in progress, move the cursor to the ALARM
REC MODE SET setting in menu 1 and then turn the shuttle dial
clockwise. The motion sensor screen appears, so use this screen
to change the LEVEL setting to "OFF".
English
PRE-ALARM RECORDING
: ON
REC CYCLE : A0.13SEC.
DURATION: 5SEC
=> (01677 ALARMS CAN BE RECORDED)
ALARM TRIGGER
: ALARM
MOTION SENSOR
->
PRE-ALARM RECORDING
: ON
REC CYCLE : A0.13SEC.
DURATION: 5SEC
=> (01677 ALARMS CAN BE RECORDED)
ALARM TRIGGER
: SENSOR
MOTION SENSOR
->
Built-in motion sensor settings
The monitor screen (-: 8x10) can be displayed on the monitor screen
so that detection of suspicious people (alarms) can be carried out
more easily. The default setting is for all motion sensors to be "OFF",
so that they cannot detect the movement of objects.
A
O F F ( - )
A
O N (ú)
( )
-
ú
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
B
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LEVEL : OFF
D
Motion sensor screen
Use the jog dial to move the cursor to MOTION SENSOR, and then
turn the shuttle dial clockwise.
The motion sensor screen appears over the normal screen.
A
When the sensors are set to "OFF" (-) and the shuttle dial is
turned clockwise, the sensor is changed to "ON" (ú). The setting
switches between "ON" and "OFF" each time the shuttle dial is
turned clockwise.
B
When the jog dial is turned counterclockwise, the cursor moves
past "EXIT" and "LEVEL: OFF", and then moves again from the
bottom to the top.
C
When the jog dial is turned clockwise and the cursor reaches the
bottom, it moves past "LEVEL: OFF" and "EXIT" and then moves
to the top.
D
The sensitivity can be adjusted when the sensor is set to "ON"
(ú). Turn the jog dial to select "LEVEL: OFF", turn the shuttle dial
clockwise, and then turn the jog dial to adjust the sensitivity.
(OFF 1 – 10: The sensitivity increases as the number becomes
lower.)
E
If the cursor is at "EXIT" and the shuttle dial is turned clockwise,
the display returns to the ALARM REC MODE SET screen.
57
C
-
-
-
-
-
-
-
-
<ALARM REC MODE SET>
-
-
-
-
PICTURE QUALITY
: ENHANCED
FRAME/FIELD RECORDING : FIELD
-
-
-
-
AUDIO RECORDING
: OFF
-
-
-
-
ALARM RECORDING
: OFF
REC CYCLE : 0.10 SEC.
DURATION: 5SEC
-
-
-
-
PRE-ALARM RECORDING
: ¤¤¤
-
-
-
-
REC CYCLE : ¤¤¤ SEC.
DURATION: ¤¤¤
=> (46400 ALARMS CAN BE RECORDED)
-
-
-
-
ALARM TRIGGER
: ALARM
E
EXIT
MOTION SENSOR
->