INTERFACE SPECIFICATIONS
Command Table (Table 4)
The following table shows all of the commands that can be processed by the digital video recorder.
If a command sent does not correspond to a digital video recorder function, the command is received but no operation is carried out.
Upper bit
0
Lower bit
0
1
2
3
4
5
6
7
8
9
A
ACK
B
NAK
C
D
E
F
Upper bit
8
Lower bit
0
1
2
3
4
5
ZOOM (MPX)
6
7
8
9
A
B
C
CHANNEL
D
COPY
E
OSD/EXIT
F
: Command for RS-485 only.
English
1
2
PLAY
STOP
9
A
FF/ALARM F
REW/ALARM R
STATUS LOG2
STATUS LOG1
3
4
SHIFT←
SEARCH
STILL
B
C
STATUS
UPLOAD
REC
REC STOP
75
5
6
TIMER ON/OFF
SHIFT→
SHIFT↑
SHIFT↓
SHIFT+
/RP UP
SHIFT–
/RP DOWN
SECURITY
LOCK ON
GROUP SET
GROUP
CHECK
GROUP
CLEAR
D
E
CLOCK
ADJUST
MENU RESET
SENSE
MENU
MENU
DOWNLOAD
CLOCK
DOWNLOAD
*RS-485 SEND
*RS-485 RCV
7
MENU
F
REC/DUB
REQUEST
START
CMF.