2.4

Wiring details

Please see the image below for the AC and DC wiring details.
① Please consult the following table to determine the correct battery cable and fuse size
for each model. Using a smaller cable size or a longer cable will cause additional losses
and may result in improperly charged batteries. Fire and burning hazards are present if
the battery cables are insufficiently sized for the expected current. Battery cable
lengths longer than 6 meters, are not recommended.
Model
2
OC
12-40
Cable size
(length ≤ 3 m)
2
16mm
(AWG6)
9
Cable size
(length = 3 to 6m)
2
25mm
(AWG4)
Battery fuse
(quick type)
50-70Amp