If the charger was not operating in a float mode prior to activating the equalize process, it
will first perform a full charge cycle before starting the 1 hour equalize stage.
2
The Omnicharge
will allow a maximum equalization time of 1 hour before it automatically
jumps back to the Float stage. If the specific gravity of each cell does not match the battery
manufacturer's specifications yet, you can initiate a new 1 hour equalization cycle by
pressing the SET and NEXT (>) buttons for 5 seconds again and follow the steps as described
above.
Always keep on checking the specific gravity of each cell repeatedly during the equalization
process. When these values are correct, you can manually exit the equalization process by
pressing the SET and NEXT (>) for 5 seconds. The charger will then return to the Float stage.