Battery type
12V
GEL
14.2V
AGM
14.7V
Lithium
14.4V
* Default setting for Lithium is No-Float (Mode=2)
When you wish to change the battery type, one or more default settings, or just review all
parameter values, please check the next chapter for the correct procedure.
Invalid battery type settings can cause serious damage to your batteries and/or connected
battery loads. Always consult your battery's documentation for the correct charge voltage
settings.
4.1
Setting up battery outputs 1, 2 and 3
All settings can be changed on the battery charger's frontpanel via an easy to use interface.
Settings can also be changed via the TBS Dashboard application. Depending on the device
running Dashboard, you either need a QuickLink to USB Communication kit (art# 5093120)
or a QuickLink to Bluetooth Communication Kit (art# 5092230). In this manual however, we
will limit the setup procedure explanation using the frontpanel controls only.
To enter the setup screens of the Omnicharge
mode, the MENU button needs to be pressed for approximately 3 seconds. This
button also needs to be pressed for 3 seconds again to save any changed
settings and jump back to the normal operating mode. Please note that when
no buttons are touched for approximately 20 seconds while running in the
setup mode, the Omnicharge
operating mode again without saving any changed setup parameters.
When the setup mode has been entered, the display shows the image indicated on the left
below. Pressing the NEXT (>) button allows you to browse through all five main setup
sections.
Configure battery bank 1
Absorption
24V
28.4V
29.4V
28.8V
!
CAUTION
2
will automatically return to the normal
NEXT
Float
12V
24V
13.5V
27.0V
13.6V
27.2V
13.3V*
26.6V*
2
from the normal operating
Configure battery bank 2
17
Restart
12V
24V
12.5V
25.0V
12.5V
25.0V
12.6V
25.2V
NEXT