10. MALFUNCTION
1. DESCRIZIONE DEI COMPONENTI
Malfunction
NO
Name
State of tests:
24
Rated compressor
frequency
State of tests:
25
Maximum frequency
compressor
State of tests:
26
Intermediate frequency
compressor
Compressor overcurrent
27
protection
Abnormal capacitor
28
charge
Abnormal temperature
29
sensors module
High temperature
30
protection IPM module
Reduced frequency due
31
to high temperature
during the heating
32
Ionizer Protection
Compressor overload
33
protection
34
System is abnormal
78
Display Method of Indoor Unit
Indicator Display ((during
blinking, ON 0.5s and OFF 0.5s)
Display
RUN
COOL
P1
P2
P3
OFF 3s
and blink
P5
15
times
PU
P7
P8
OFF 3s
and blink
H0
10
times
OFF 3s
and blink
H2
2
times
OFF 3s
and blink
H3
3
times
OFF 3s
and blink
H4
3
times
A/C status
HEAT
Cooling and dehumidification:
compressor and outdoor fan stops
while the indoor fan continues to run.
Heating: the entire unit stops.
OFF 3s
Cooling and dehumidification:
and blink
compressor and outdoor fan stops
17
while the indoor fan continues to run.
Heating: the entire unit stops.
times
OFF 3s
Cooling and dehumidification:
and blink
compressor and outdoor fan stops
18
while the indoor fan continues to run.
Heating: the entire unit stops.
times
OFF 3s
Cooling and dehumidification:
and blink
compressor and outdoor fan stops
while the indoor fan continues to run.
19
Heating: the entire unit stops.
times
The entire unit operate normally,
but the working frequency of the
compressor is reduced
The entire unit is operating normally.
Cooling and dehumidification:
compressor and outdoor fan stops
while the indoor fan continues to run.
Heating: the entire unit stops.
Cooling and dehumidification:
compressor and outdoor fan stops
while the indoor fan continues to run.
Heating: the entire unit stops.
GB
GB
Possible Causes
Displayed during the test of rated
cooling or rated heating
Displayed during the test of maximum
cooling or maximum heating
Displayed during the test of
intermediate cooling or intermediate
heating
1. Voltage between L and N on the
terminal differs from 210 to 250
VAC;
2. Compressor wiring loose or sliced ;
3. Compressor damaged;
4. Overabundance or insufficent
refrigerant;
5. Poor heat exchange (exchanger
dirty or poor air circulation).
1. Voltage between L and N on the
terminal differs from 210 to 250 VAC
2. Wiring loose or sliced (the unit
must be powered off for at least
20 minutes before checking the
wiring);
3. Capacitor damaged;
4. Electronic board damaged.
Electronic board damaged.
1. Check the thermal insulation of IPM
module and the radiator (the unit
must be powered off for at least
20 min);
2. Electronic board outdoor unit
damaged.
1. Ambient temperature is too high;
2. Poor heat exchange (exchanger
dirty or poor air circulation).
1. Ionizer wiring loose or sliced ;
2. Ionizer damaged;
3. Electronic board damaged.
1. Wiring the compressor loose or
sliced (under normal conditions the
resistance to this terminal should
be less than 1 ohm);
2. Overabundance or insufficent
refrigerant.
3. Obstruction refrigerant circuit;
4. Malfunction of compressor.
1. Condensing temperature is too
high;
2. Ambient temperature too high
3. Poor heat exchange (exchanger
dirty or poor air circulation).