Valve alarm closed/Absence of water supply
20/12/2015 6 : 30 pm
Battery alarm
Preventive maintenance
This alarm appears if the REC recording
function is active when the pump water meter
and the flexible blade switch cycle counter
sends no pulse for 30 minutes (value pre-
defined in onboard software). E.g. DOSATRON
bypass valve remained accidentally closed or
break in water supply (network problem, filter
blocked, etc.)
Battery symbol appears, indicating that it
needs to be replaced – See MAINTENANCE
paragraph
Press
the replacement of the dosing assembly seals.
Factors such as the type of products dosed,
the quality of the water and, above all, the
rinsing of the pump after use may prolong or
reduce the lifetime of the seals. Pressing the
validation button brings the user back to the
current menu
A tip: The diagnosis menu enables you to
check the performance of the dosing assembly.
completed, go to the CONFIGURATION menu
(screen with circled cog)
activate it by pressing the validation button
(screen with OK struck through appears)
removes the alarm and reinitialises the
maintenance meter
©
DOSATRON INTERNATIONAL S.A.S. / 27
©
DOSATRON INTERNATIONAL S.A.S. / 63
to validate
This alarm (given as an indication) concerns
Once the maintenance has been
Wait for the maintenance screen and
Pressing the validation button again