Leaks close to the
attachment ring under the
pump body.
Leaks between the
adjustment bush and the
blocking ring.
Leaks between the body
and the lid.
Screen does not turn on
Displays incoherent alarms
Monitoring module regularly
turns off
GUARANTEE
DOSATRON INTERNATIONAL S.A.S. undertakes
to replace any original part acknowledged to be
defective over a 12-month period for the "doser"
assembly of the SD25AL5 system and over a
24-month period for the "monitoring module" part
of the system from the date of purchase by the
initial purchaser. To obtain the replacement under
guarantee the device or the separate part must be
sent back with the initial proof of purchase to the
manufacturer or to the approved distributor. It may
be acknowledged defective after verification by the
manufacturer's or distributor's technical services.
The device must be rinsed of any chemical product
and sent to the manufacturer or to the distributor
with postage paid, then it will be returned free of
charge after repair if it is covered by the guarantee.
The purpose of operations carried out under the
guarantee may not be to extend the lifetime. This
guarantee applies only to manufacturing defects.
This guarantee does not cover the defects
observed resulting from an abnormal installation
of the device, from the use of inappropriate tools,
from an installation or maintenance defect, from
an environmental accident or by corrosion due to
foreign bodies or liquids found inside or near to the
device.
Leaks
Injector sleeve seal damaged,
wrongly positioned or absent.
Doser body seal damaged,
wrongly positioned or absent.
Lid seal damaged, wrongly
assembled or absent.
Monitoring Module
Electric power supply problem
Electricity micro-cutouts
©
©
DOSATRON INTERNATIONAL S.A.S. / 34
DOSATRON INTERNATIONAL S.A.S. / 70
Position it correctly or replace it.
Position it correctly or replace it.
Position it correctly, clean seal seat
bearing or replace it.
Check the installation of your
SMART DOSING system
Check all the electric connections
(flexible blade switch sensor/water
meter pulse transmitter; the position
of your "level detection" pipe;
position of your monitoring module
in the wall support rail)
Check the condition of the 9V -
6LR61 backup battery.
For the dosing of aggressive products, please
consult your vendor before any use to confirm the
compatibility with the doser. The guarantees do not
include the seals (worn parts) or damage caused
by water impurities, such as sand. A filter (e.g.
300 mesh - 60 microns depending on the quality
of your water) must be installed at the front of the
device to validate this guarantee. DOSATRON
INTERNATIONAL S.A.S. declines any liability if the
device is used under conditions non-compliant with
the user manual instructions and tolerances.
There is no explicit or implicit guarantee relating
to other products or accessories used with
DOSATRON INTERNATIONAL S.A.S devices.
Do not hesitate to contact your distributor or
Dosatron for any after-sales service.