Programming - AUtec Modular Serie Manual De Usuario

Ocultar thumbs Ver también para Modular Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

LIMKNPU2
!
The dip switches must be programmed with the battery removed from
the transmitting unit and can be done only by authorised personnel.
DIP SWITCHES ON E16STXEU_ RADIO TRANSMITTING MODULE
The group of eight dip switches found
in the module is necessary for
programming some operations and
setting the operating frequency.
The programming set in the other
group of four dip switches must never
be modified.
DIP
MODULE
1
E16STXEU_
2(*)
E16STXEU_
E16STXEU1
3
E16STXEU2
3 - 7
E16STXEU_
8
E16STXEU_
(*) With the MK12 transmitting unit the dip switch should be at ON.
!
These eight dip switches must be programmed in the same manner as
the group of 8 dip switches (excluding DIP 1) present in the radio
module of the receiving unit (see manual).
8

PROGRAMMING

Group of 8 dip switches
POS.
ON
The transmitting unit never switches off automatically
The transmitting unit switched on without movement
OFF
commands entered switches off after approx. 3,5 minutes
ON
Deactivated of low battery warning from horn on machine.
OFF
Activation of low battery warning from horn on machine
With DIP 8 OFF, automatic scan of the frequencies in the
ON
With DIP 8 OFF, automatic scan of the frequencies in the
OFF
ON
With DIP 8 OFF, automatic scan of the frequencies in the
OFF
ON/OFF
With DIP 8 ON see "Appendix: Frequency Table"
Manual selection of frequencies with
ON
DIP 3 - DIP 7 (see "Appendix: Frequency Table")
Automatic scan mode of frequencies in the band selected
OFF
with DIP 3 (DIP 4 – DIP 7 not relevant)
Group of 4
dip switches
Group of 8
dip switches
DESCRIPTION
433.050 - 434.040 MHz
434.050 - 434.790 MHz
DON'T USE
869.700 - 870.000 MHz
Page 13

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

16stxeuE16srxeuE16scheu

Tabla de contenido