Table of Contents
Introduction............................................................................................ 2
Safety Symbols/Safety Category Ratings................................................4
RANGE Button........................................................................................6
HOLD/REL Button...................................................................................6
AC Voltage..............................................................................................8
DC Voltage..............................................................................................8
AC + DC Voltage.....................................................................................8
mV Voltage..............................................................................................9
AC and DC Current................................................................................. 9
Frequency and Duty Cycle......................................................................10
Frequency: AC Voltage/Current Function................................................ 11
Resistance..............................................................................................12
Continuity............................................................................................... 12
Capacitance........................................................................................... 13
Diode Test.............................................................................................. 13
Temperature............................................................................................14
SAVE Function........................................................................................14
PEAK Mode............................................................................................. 1 5
MENU Functions
Start Recording..................................................................17
Bluetooth........................................................................... 23
Beeper On/Off....................................................................24
Date/Time.......................................................................... 25
Meter Info.......................................................................... 27
Recharging Battery........................................................................... .......28
.....................................................................................30
Warranty.................................................................................................. 32
1
Introduction
The Southwire 15190T MaintenancePRO
MApp
Mobile App features a high resolution color display with graphing
TM
capabilities, rechargeable Lithium Ion battery, rugged double molded housing,
CAT IV 600V/CAT III 1000V safety rating and an intuitive menu driven operating
system. Advanced functions include Frequency, Duty Cycle, Capacitance,
Temperature, Max/Min/Average, and Peak Hold. A recording mode with a trend
chart is provided for detailed circuit analysis. The 15190T wirelessly transmits
data to the MApp
mobile app via Bluetooth
TM
organize and share datalogs as well as take measurements from a safe distance.
Visit nextgenmeters.southwiretools.com for mobile app download information.
This meter is fully tested and calibrated and, with proper use, will provide many
years of service.
WARNINGS
• Read, understand and follow Safety Rules and Operating Instructions in
this manual before using this meter.
• The meter's safety features may not protect the user if not used in accordance
to the manufacturer's instructions.
• Ensure that the test leads are fully seated in the input jacks and keep
fingers away from the metal probe tips when taking measurements.
• Before changing functions using the selector switch, always disconnect the
test leads from the circuit under test.
• Use only UL listed test leads with the proper safety category rating.
• Comply with all applicable safety codes. Use approved personal protective
equipment when working near live electrical circuits - particularly with regard
to arc-flash potential.
• Use caution on live circuits. Voltages above 30 V AC rms, 42 V ac peak,
or 60 V dc pose a shock hazard.
• Do not use meter or test leads if they appear damaged.
• Verify operation before using meter by measuring a known live voltage.
• Do not use the meter in wet or damp environments or during electrical storms.
• Do not use the meter near explosive vapors, dust or gasses.
• Do not use the meter if it operates incorrectly. Protection may be compromised.
• Do not operate meter while Low Battery warning is on.
(Battery Indicator will flash). Recharge the battery before using.
• Do not apply voltage or current that exceeds the meter's maximum rated
input limits.
Color Screen Multimeter with
TM
allowing you to view, save,
®