Displays - Dal Zotto Edy Manual Del Usuario

Ocultar thumbs Ver también para Edy:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Display
off
staRt
pellet feeDing
ignition
BuRning
opeRant
MoDulation
BuRn pot Cleaning
final Cleaning
stanD-By
stanD By ext
Cooling stanD-By
Cool. stDBy -
BlaCk out
low
Hot
seRviCe
50
Reason
Stove off
The start-up phase is in progress
The feeding of the pellet during the ignition phase is in progress
The ignition phase is in progress
The start-up phase is in progress
The normal work phase is in progress
The stove is modulating
The automatic burn pot cleaning is in
progress.
When the stove is switched-off, final cleaning is in progress. The final cleaning phase lasts about 10
minutes.
Stove off due to temperature reached
and in stand-by for re-ignition.
Stove off due to an external
thermostat, waiting for re-ignition
A new ignition is attempted when
the stove has just been switched-off
The stove is cooling due to black out
Room thermostat set at minimum
value.
Set room thermostat set at maximum
value.
When this message appears, contact the authorised technician for ordinary cleaning of the appliance.
If cleaning is not performed, the message will be displayed at every ignition but without interrupting
normal stove operation.

Displays

The automatic burn pot cleaning (not in 1st power) is performed
at pre-established intervals of continued working.
To deactivate the STAND-BY function see the specific chapter.
To deactivate the STAND-BY function see the specific chapter.
When the stove switches off, it is necessary to wait for the
complete shutdown of the fumes motor before cleaning the burn
pot.
The stove can only be re-ignited when these operations have
been performed.
On completion of the cooling phase, it will re-ignite automatically.
In this way the stove only works at 1st power independently
from the power set. To exit this function just raise the room
temperature using button 4 and then key 2.
The stove works at set start, without ever modulating. To escape
this function just lower the set temperature using key 4 and then
key 1.
ENGLISH
solution
-
-
-
-
-
-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

GabryGabry eliteStefyRitaRita elite

Tabla de contenido