1. Prescribed use of the CorroScout
CorroScout
1.1 Measuring the drive potential (direct voltage)
of
Insulated installed Mg sacrificial anodes as well as
CORREX
Measuring ranges:
2 V for Mg sacrificial anodes and
20 V for CORREX
1.2 Measurement of protective currents (direct voltage)
In the measuring ranges
20 mA (regularly) and
200 mA.
1.3 Measuring the mains voltages
230 V AC and
115 V AC
For testing sufficient mains voltage supply when using CORREX
impressed current anode systems
1.4 Measurement of the potential balance resistor
When using storage water heaters with insulated installed electric
tubular heating element or other non-enamelled flat tubular or finned
tubular heaters installed with potential balance resistor.
®
500 is a multi-function anode tester. Its purpose is:
®
impressed current anodes against boiler or tank.
®
impressed current anodes
CorroScout
®
500 Operating Instructions
®
500
®
500
®
21