3. PROGRAMMING OF THE FUNCTIONS
BY
R-CONTROL TRANSMITTERS
Using a transmitter of the range R-CONTROL it is possible changing the functions of the actuator.
R-CONTROL is equipped with a 4 switches dip-switch thanks to which it is possible to change the desired
functions: set on ON the switch corresponding to the function required and follow carefully the dedicated
procedure.
WARNING: all the other switches have to be set on OFF
UP
STOP
DOWN
SELC
SELG
DIP-SWITCHES
PROG
3.1 Switch 1: Storage of the transmitters
To store a transmitter TX1 on a blank control unit proceed as follows:
WARNING: the first transmitter stored fixes the direction of motion of the motor.
a)
Power only the control unit to be programmed.
b)
Set on ON the switch 1 of the transmitter.
c)
R6-CONTROL only: press several times the key SELC of the transmitter TX1 until displayed the selected channel (by the leds
or on the display).
d)
Press and keep pressed (for about 5 seconds) the key PROG of the transmitter TX1 until the motor starts to move in one way.
e)
Release the key PROG: the motor stops.
f)
Press the keys UP or DOWN depending on the way of motion of the actuator before stopping:
-
if the actuator was going up, press the key UP; direction acquired:
the key UP moves the actuator UPWARDS, the key DOWN moves the actuator DOWNWARDS.
-
if the actuator was going down, press the key DOWN; direction acquired:
the key DOWN moves the actuator DOWNWARDS, the key UP moves the actuator UPWARDS.
g)
Set the switch 1 to OFF.
18
DIP
FUNCTION
1
Storage of the transmitters
3
Deletion of all the stored transmitters
2-4
NOT USED