Compilation and storage of technical
documentation:
Sven Zimmermann
VIKING GmbH
The year of manufacture and serial
number appear on the identification plate
of the machine.
Measured sound power level:
94.0 dB(A)
Guaranteed sound power level:
96 dB(A)
Langkampfen,
2017-01-02 (YYYY-MM-DD)
VIKING GmbH
Head of Design
18. Technical specifications
ME 443.1 / ME 443.1 C:
Serial number
6338
Motor, design:
Electric motor
Manufacturer:
Cleva
type:
Universal AC
electric motor
Voltage:
230 V~
Power input:
1500 W
Frequency:
50 Hz
Fuse:
7 A
0478 121 9920 D - EN
ME 443.1 / ME 443.1 C:
Protection class:
II
Type of protection:
IPX 4
Cutting utilities:
Cutter bar
Cutting width:
41 cm
Speed of cutting
utilities:
2900 rpm
Cutter bar drive:
permanent
Tightening torque for
blade fastening
screw:
10 - 15 Nm
Wheel diameter
(front):
180 mm
Wheel diameter
(rear):
200 mm
Grass catcher box:
55 l
Cutting height:
25 - 75 mm
ME 443.1:
In accordance with Directive 2000/14/EC:
Guaranteed sound
power level L
96 dB(A)
WAd
In accordance with Directive 2006/42/EC:
Sound pressure level
at workplace L
82 dB(A)
pA
Uncertainty K
2 dB(A)
pA
Specified vibration characteristic in
accordance with EN 12096:
Measured value a
1.40 m/sec²
hw
Uncertainty K
:
0.70 m/sec²
hw
Measurement in accordance with
EN 20643
L/W/H:
138/49/107 cm
Weight:
20 kg
Weight (Great Brit-
ain only):
21 kg
ME 443.1 C:
In accordance with Directive 2000/14/EC:
Guaranteed sound
power level L
:
96 dB(A)
WAd
In accordance with Directive 2006/42/EC:
Sound pressure level
at workplace L
82 dB(A)
pA
Uncertainty K
2 dB(A)
pA
Specified vibration characteristic in
accordance with EN 12096:
Measured value a
1.30 m/sec²
hw
Uncertainty K
:
0.65 m/sec²
hw
Measurement in accordance with
EN 20643
L/W/H:
138/49/108 cm
Weight:
22 kg
19. Troubleshooting
If necessary, contact a specialist
dealer; VIKING recommends VIKING
specialist dealers.
Fault:
Motor does not start
Possible cause:
– No mains voltage
– Connection cable, plug, plug connector
or switch defective
– Start button not pressed
– Motor is overloaded because the grass
is too tall or too wet
– Motor overload protection activated
– Mower housing is blocked
– Fuse in plug faulty (GB version)
Remedy:
– Check fuse (
11.1)
45