DUSI01EN - v5
6 - TROUBLESHOOTING
OPTIMA selector
If the monitoring programme detects a
problem in door operation, a numerical code
will flash the display.
In most cases, to restore door operation simply select the door OPEN mode and then the door AUTOMATIC mode. If
the problem persists, contact an manusa authorised Technical Service.
MALFUNCTION
POSSIBLE CAUSE
a. Mains overcurrent
OVERCURRENT
b. Short circuit in motor or
circuit.
Overcurrent in motor
a. Panic break-out leaves
SOS
open.
b. Emergency push button
activated.
Emergency signal activated
OBST CLOSING
Obstruction
closing cycle.
Obstruction on closing
The outside key switch has
OUTSIDE KEY
not been removed from the
SWITCH
device.
Outside key switch activated
DOOR PARAM MEM.
Parameter
falling.
Parameters memory
Obstruction
OBST. OPENING
opening cycle.
Obstruction on opening
PHOTOCELL
The IR barriers are blocked
for a period > 1'.
IR barriers
Fire alarm signal activated.
FIRE ALARM
Infrared barriers
a. Low battery.
LOW BATTERY
b. Low mains voltage.
Panic door system
NOTE: The features included in this document are given for infor-
mation purposes only, and are not binding.
The manufacturer reserves the right to modify its products without prior
notice.
Last updated: May 2010
SOLUTION
Change to OPEN followed
by AUTOMATIC mode to
resume normal operation. If
the problem persists, call
the Technical Service.
a. Check position of panic
break-out leaves.
b. Check the emergency push
button.
within
the
Ch ec k
an d
rem o ve
a ny
obstruction within the door
closing cycle. Then resume by
changing the door to OPEN
followed by AUTOMATIC
mode
Remove the key from the
outside key switch device.
memory
is
Call Technical Service.
within
the
Ch ec k
an d
rem o ve
a ny
obstruction within the door
opening cycle. Then resume by
changing the door to OPEN
followed by AUTOMATIC
mode
Check the alignment of the
IR barriers.
Check fire alarm system.
I f
t h e
d o o r
w a s
disconnected,
leave
the
door connected during 24
hours
to
charge
the
batteries. If the warning
persists, call the Technical
Service.
AUTOMATIC DOOR WITH VISIO OPERATOR - USER MANUAL
SMART selector
If
the
problems in the door operation, a numerical
code flashes in the display along with an
icon indicating the problem.
MALFUNCTION
POSSIBLE CAUSE
Radar contact permanently
INSIDE RADAR
closed for a period of > 1'.
Malfunction in internal radar
Radar contact permanently
OUTSIDE RADAR
closed for a period of > 1'.
Malfunction in external radar
The
PHOTOCELL 3
blocked.
IR Barrier 3
Malfunction in the control
MOTOR CONTROL
board.
Malfunction in the motor control
Safety
SAFETY SENSOR
activated.
Malfunction on side sensors
The LCD screen
The selector has no power.
does not light up
No communication with the
LOADING DATA
operator.
Communication fault occurs
when the following message
appears on screen:
"loading data"
HEAD OFFICE
Av. Vía Augusta, 85-87, 6th
08174 Sant Cugat del Vallés
Barcelona - Spain
Tel. +34 902 321 400
Fax +34 902 321 450
24
monitoring
programme
SOLUTION
Call Technical Service.
Call Technical Service.
third
IR
barrier
is
Call Technical Service.
Change to OPEN followed
by AUTOMATIC mode to
resume normal operation. If
the problem persists, call
the Technical Service.
opening
signal
Verify that there is no object
within the sensor detection
area.
Check door power supply.
Call Technical Service.