If the motor does not work or does not extract
water, try to trace the fault from the list of the most
common faults and the possible solutions for them
as set out in later pages.
4.2 - Starting up the pump with no-water
protection device (DORINOXCONTROL)
When the power switch is switched on the pump
starts immediately. The current indicator LED will
light up (LINE+RUN).
During this operation keep an outlet tap open in
order to bleed any air from the installation. Once
the installation has been bled, close the tap and the
unit will stop, leaving the (LINE) indicator LED lit up.
If (ON) is pressed the equipment will start to run
unless it fails to detect water. If the pump is not well
primed at start-up, or if there is no water to supply
to it, the pump will stop running.
See fig.6 for the distribution of the indication LEDs.
If the motor does not work or does not extract
water, try to trace the fault from the list of the most
common faults and the possible solutions for them
as set out in later pages.

5. MAINTENANCE

Under normal conditions these pumps require no
special or planned maintenance.
Clean the pump with a damp cloth without using
harsh products.
If the pump is not to be operated for a long
period it is recommended to remove it from
the installation, drain down and store in a dry,
well ventilated place.
ATTENTION: In the event of faults or
damage occurring to the pump, repairs and
replacing the power cable should only be
carried out by an authorised service agent.
The Official Technical Services list is in
www.pompesguinard-loisirs.fr
When the pump is eventually disposed of, please
note that it contains no toxic or polluting material.
All main components are material identified to allow
selective disposal.
6.
PLATE SHOWING CHARACTERISTICS
DESCRIPTION
1
Item reference
2
Voltage + frequency + item specifications
3
Flow
4
Pressure
5
Nominal voltage, no. stages, alternate current symbol and frequency
6
Capacitor (Single-phase model)
7
EC mark + year of manufacture
8
Humidity protection level
9
Minimum working pressure
10
Maximum pressure
11
Pump serial no. (Fig.4)
12
Max. liquid temperature
13
Motor max. nominal output (P2)
14
Electric pump unit absorbed power(P1)
15
Designated motor insulation
16
Continuous operation symbol
17
Maximum nominal intensity at nominal voltage
18
Name and address of vendor responsible for the product

7. TECHNICAL DATA

Liquid temperature... ...................... .4ºC - 40ºC
Ambient temperature: ...................... 0ºC - 40ºC
Storage temperature: .................. -10ºC - 50ºC
Ambient relative humidity, max: ................ 95%
Motor class I.
Other data see Figure 2.