Screw back screw C until the location bore is free.
Insert cartridge holder 2 with the clamping surface towards the screw.
Clamp cartridge holder 2 with screw C to 5 Nm.
Fit cartridge H1 or H2, adjust using graduated scale and fasten to 5 Nm using cheese-head screw 6
(spring disc/plain washer).
Loosen screw A.
Place tool on pre-setting device: adjust finely using graduated dial.
One turn of the graduated dial corresponds to a ⌀ adjustment of 1 mm.
Using the scale, adjustments of 0.01 mm can be made from graduation to graduation or of 2 μm using
the vernier.
Clamp slider B to 6 Nm with screw A.
Check the diameter on the pre-setting device and correct if necessary.
The following fundamentally applies:
For diameter adjustment, first of all adjust the attachment components to a maximum or within the scale
range, and then finely adjust the slide.
No warranty is given for possible combinations not described here.
Always use the bridge and the cartridge in the scale range and secure using the applicable
threaded fitting.