GB
10.
Maintenance and care
The complete jaw mechanism must be maintained regularly.
10.1
To clean or change the jaws
•
Disconnect the tool from the compressed air supply.
•
Unscrew steel head sleeve (No. 2) and clean inside if necessary.
•
Use 17 mm and 14 mm open-ended spanners to release jaw housing (No. 3) from lock
activator (No. 16), clean or replace if worn.
•
Remove jaws (No. 4), clean and oil sliding surfaces; replace if worn.
•
Check jaw pusher (No. 5) for wear; replace if necessary.
•
Reassemble the jaw mechanism in reverse order; screw together No. 3 & 16; tighten No. 2.
10.2
To top up oil
•
Unscrew steel head sleeve (No. 2) and jaw housing (No. 3).
•
With the trigger button (No. 30) pressed, disconnect the riveting tool from the compressed
air supply (air piston in upper end position).
•
Undo oil refill screw plug (No. 8) and push lock activator (No. 16) into the rear end
position by hand.
•
With supplied refill bottle – fit filler piece deep into the tool head – top up oil free of bubbles.
•
Moderately tighten the refill screw plug with seal.
•
Connect the riveting tool to the compressed air supply.
•
Drain off overfilled oil by releasing the refill screw plug (No. 8) and then moderately
tighten again.
•
Fit jaw housing (No. 3) and, with the trigger button (No. 30) pressed, fit and tighten steel
head sleeve (No. 2).
10.3
Storage
•
Store the riveting tool in a dry place where there is no danger of frost.
20