7.1
Selecting and changing the nosepiece
Caution:
Always fit the nosepiece corresponding to the size of the blind rivet (refer to table in
Section 6).
To change the nosepiece:
•
Disconnect the tool from the compressed air supply.
•
Unscrew nosepiece from steel head sleeve.
•
Screw in corresponding nosepiece and tighten.
7.2
To set a blind rivet
•
Connect the riveting tool to the compressed air supply.
•
Insert the blind rivet in the nosepiece and fit as far as it will go in the hole in the material
to be joined.
•
Press trigger until the mandrel breaks off.
•
Release trigger.
•
The spent mandrel is automatically conveyed into the spent mandrel container.
8.
Sucking in and holding a blind rivet
Special function VAS
•
The setting screw marked with "VAS" is reached with the supplied ball end screwdriver.
•
Turning the screw 1 to max. 1.5 turns clockwise creates the suction air that holds the
blind rivet in the nosepiece.
•
Only turn the setting screw so that the suction air holds the vertical blind rivet against the
nosepiece.
•
Turning the screw anticlockwise shuts off the suction air.
9.
Emptying the spent mandrels from the container
Caution:
The spent mandrel container must be emptied regularly; overfilling will cause the
riveting tool to malfunction.
•
Disconnect the tool from the compressed air supply.
•
Open the spent mandrel container by turning the outer casing, empty spent mandrels into
suitable container and dispose of in corresponding recycling system.
GB