6.1
Commissioning
3
Note:
This pumps runs as long as the ON/
OFF switch is switched ON.
1. Plug power cable in.
2. Switch pump on with the ON/OFF
switch.
3. Open pressure line (open tap or
spray nozzle).
4. Check to see that the water comes
out!
A
Caution!
With a closed pressure line do not let
pump run for more then 10 minutes,
otherwise there could be damage by
the water overheating in the pump.
6.2
Starting a pump with
Hydromat (HWA)
3
Note:
A pump with installed Hydromat is op-
erational as long as the ON/OFF switch
is turned ON.
The Hydromat
– starts the pump when water is re-
quired (when opening the discharge
line the water pressure falls off to
below the cut-in pressure);
– turns the pump off approx.
10 seconds after closing the dis-
charge line (water pressure increas-
es in the closed discharge line);
– turns the pump off to prevent dry
running when no water is pumped
(air in suction line).
13
14
15
13 Power indicator (green)
14 Pump indicator (white)
15 Reset button
1. Plug power cable in.
2. Check to see that the power indica-
tor (13) is illuminated.
3. Open discharge line.
4. Press the reset button (15). The
pump will start running.
If there is no water pumped after
approx. 10 seconds the Hydromat
will turn off. Then press and hold
the reset button (15) until water
emerges.
If no water emerges after approx. 3
minutes, check the suction line.
7.
Care and Maintenance
A
Danger!
Prior to all servicing:
1. Turn OFF.
2. Unplug.
3. Ensure that pressure is relieved
from the pump and connected ac-
cessories.
Service and repair work other than
described here must be left to quali-
fied specialists.
7.1
Danger of freezing
A
Caution!
Frost damages the pump and acces-
sories, as both always contain wa-
ter!
When there is danger of freezing,
dismount the pump and accesso-
ries and store at a frost-free loca-
tion (see below).
7.2
Pump Dismounting and
Storing
1. Turn pump OFF and unplug.
2. Open pressure line (open tap or
spray nozzle) and drain water com-
pletely.
3. Drain pump completely; to do so re-
move the drain plug from the pump
ENGLISH
4. Disconnect suction and pressure
lines from the pump.
5. Store equipment in a frost-free room
(at least 5 °C).
8.
Troubleshooting
A
Danger!
Prior to all servicing:
1. Turn OFF.
2. Unplug.
3. Ensure that pressure is relieved
from the pump and connected ac-
cessories.
8.1
Troubleshooting Guide
Pump does not run:
Pump not turned ON.
Start pump at the ON/OFF
switch.
– Hydromat has cut out.
Press the reset button.
If no water is pumped after ap-
prox. 10 seconds, press and hold
reset button until Water emerges.
– No mains voltage.
Check cables, plug, outlet and
mains fuse.
– Mains voltage too low.
Use only extension cables with
sufficient lead cross section (see
"Technical Specifications").
– Motor overheated; motor protection
relay tripped.
After cooling the pump will switch
ON again.
Ensure sufficient ventilation,
keep vent slots clear.
Observe max. temperature of the
pumped medium.
– Motor hums but does not start.
With the motor switched OFF,
put screwdriver or similar through
the fan cover's vent slots and
turn the fan.
– Pump blocked or out of order.
Disassemble pump and clean.
Clean diffusor, replace if neces-
sary.
Clean impeller, replace if neces-
sary.
15