ENGLISH
Pump does not prime correctly or
runs very noisily:
– Lack of water.
Ensure there is a sufficient water
supply.
– Suction line leaky.
Seal suction line, tighten screw
fittings.
– Suction head too high.
Observe max. suction head.
Install check valve, fill suction
line with water.
– Suction strainer (optional accesso-
ry) blocked.
Clean, replace if necessary.
– Check valve (optional accessory)
blocked.
Clean, replace if necessary.
– Water leaks between motor and
pump, Duocone seal worn.
Replace Duocone seal.
– Pump blocked or out of order.
see above.
Pressure too low:
– Suction line leaky or too much suc-
tion head.
see above.
– Pump blocked or out of order.
see above.
9.

Repairs

A
Danger!
Repairs to electric tools must only
be carried out by a qualified electri-
cian!
Electric tools in need of repair can be
sent to an authorised service center in
your country. See spare parts list for
address.
Please attach a description of the fault
to the electric tool.

10. Disposal

Power tools do not belong in the house-
hold rubbish. According to European
Directive 2002/96/EC on waste electri-
16
cal and electronic
equipment, electrical waste must be
collected separately and taken
to an environmentally friendly recycling
facility.
Contact your local council for informa-
tion on disposal of the used tool.
All packaging materials are recyclable.
11.

Available Accessories

For this pump the following accessories
are available from your dealer.
3
Note:
Illustrations and stock numbers are
shown at the end of this manual.
A Pump Installation Package, 
(MSS 310 – HWA/P), complete with
double nipple, check valve, filter
short, washable filter cartridge, spi-
ral hose assembly 1 m, thread seal-
ing tape.
B Pump Installation Package, 
(MSS 380 – HWW), complete with
double nipple, check valve, filter
short, washable filter cartridge, spi-
ral hose assembly 1 m, thread seal-
ing tape.
C Pump Installation Package, 
(MSS 200 – HWW/P), complete
with double nipple, check valve, fil-
ter short, washable filter cartridge,
spiral hose assembly 1 m, thread
sealing tape.
D Pump Installation Package, 
(MSS 1000 – HWA), complete with
double nipple, check valve, filter
short, washable filter cartridge, spi-
ral hose assembly 1 m, thread seal-
ing tape.
E Filter (for garden pumps), 
1" connection, short, 
c/w washable synthetic material fil-
ter cartridge.
F Filter (for domestic water systems), 
1" connection, short, 
c/w washable synthetic material fil-
ter cartridge.
G Spiral Suction Hose 1" (standard)
H 4 m, c/w quick release screw fitting
and strainer with foot valve;
I
7 m, c/w quick release screw fitting
and strainer with foot valve;
J Spiral Suction Hose 1" (profession-
al)
K 1.5 m, both ends with quick release
screw fitting;
L 4 m, c/w quick release screw fitting
and strainer with foot valve;
M 7 m, c/w quick release screw fitting
and strainer with foot valve;
N Reinforced Hose 500 mm
O Multi-adapter 1"
ideal for connecting to pumps with
1" AG connector
(AG=male thread, IG=female
thread)
P Hydrostop, 
for automatic stopping when there is
a lack of water, prevents the pump
from running dry.
Q Dry-running Stop Switch, 
with 10 m cable, keeps the pump
from running dry when pumping
from tank, pool, etc.
R Thread Sealing Tape, 12 m roll.
S Washable Filter Cartridge, short, 
for mechnical pre-filtering of sand,
reusable.
T Washable Filter Cartridge, long, 
for mechnical pre-filtering of sand,
reusable.

Publicidad