Leroy-Somer VARMECA 10 Instrucciones De Uso página 34

Ocultar thumbs Ver también para VARMECA 10:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 75
LEROY-SOMER
1.4.2 - Configuration option 1: 2 preset speeds - 2 operating directions
MAINS
SUPPLY
Terminals
+10 V analogue source
1
Rated current: 3 mA
2
Analogue input not used
Analogue output 0 to +10 V
Rated current: 3 mA
3
0 V = zero speed
10 V = max. speed
4
0 V - common with terminal 6
5
Logic input S1
6
0 V - common with terminal 4
Logic input
7
run reverse/stop
Logic input
8
run forward/stop
Relay output 250 V - 1A
9 - 10
32
PARAMETER-SETTING MANUAL
VARMECA 10
Variable speed motors and geared motors
GENERAL INFORMATION
L1
L2
L3
PE
9
Fault
relay
10
Specifications
Switched off or faulty
On
1
2
3
0-10V speed image output
4
0V
S1
5
Preset speed selection
6
0V
7
Run reverse / stop
8
Run forward / stop
Associated parameter setting
CDC-VMA
Terminal block configuration
P14 = 1
P15 = VP1-1(Hz)
P16 = VP2-1(Hz)
MINI DIP K4 = ON
Reference
VP1-1
VP2-1
Setting other parameters
see sections 2 and 3
Ref. 3264 - 4.33/b -1.00
PEGASE VMA 10
OPTION 1
VP1 OPTION 1(Hz)
VP2 OPTION 1(Hz)
S1
1
0

Publicidad

Tabla de contenido
loading