LEROY-SOMER
1.4.4 - Configuration option 3: correction of an external reference with the speed control button - 2
operating directions - enabling/disabling the control button
MAINS
SUPPLY
Terminals
+10 V analogue source
1
rated current: 3 mA
Analogue reference input 0 to +10 V or
2
4 - 20 mA
Analogue output 0 to +10 V
Rated current: 3 mA
3
0 V = zero speed
10 V = max. speed
4
0 V - common with terminal 6
Logic input, for enabling/disabling the correction
5
S1 open = correction possible
S1 closed = no correction
6
0 V - common with terminal 4
Logic input
7
run reverse/stop
Logic input
8
run forward/stop
Relay output 250 V - 1A
9 - 10
34
PARAMETER-SETTING MANUAL
VARMECA 10
Variable speed motors and geared motors
GENERAL INFORMATION
Local button :
adjustment from 0 to 100%
of the external reference
L1
L2
L3
PE
9
Fault
relay
10
Specifications
Switched off or faulty
On
1
2
External
3
reference
0-10V / 4-20mA
4
0V
S1
5
Enable / disable local button
6
0V
7
Run reverse / stop
8
Run forward / stop
Associated parameter setting
CDC-VMA
P14 = 3
MINI DIP K4 = ON
Reference
0 - 10 V
4 - 20 mA
Setting other parameters
see sections 2 and 3
Ref. 3264 - 4.33/b -1.00
Version with remote
potentiometer
+10V
1
2
10KΩ
3
4
0V
PEGASE VMA 10
Terminal block configuration
OPTION 3
Mini DIP K1
ON
OFF