Technical data
Binoculars
Magnification . . . . . . . . . . . . . . . . . . . . . 7 x
Prism system . . . . . . . . . . . . . . . . . . . . . . Porro
Objective diameter. . . . . . . . . . . . . . . . . . . 50 mm / 1.97 in
Exit pupil . . . . . . . . . . . . . . . . . . . . . . . . 7 mm / 28 in
Field of view at 1.000m / 1.000 yds. . . . . . . . . . . 126 m / 379 ft. at 7.2°
Diopter adjustment . . . . . . . . . . . . . . . . . . -/+ 3 diopters
Eye relief . . . . . . . . . . . . . . . . . . . . . . . . 22 mm / 87 in
Twilight factor . . . . . . . . . . . . . . . . . . . . . 18.7
Operating temperature . . . . . . . . . . . . . . . . -10° C to +50° C / 14° F to 122° F
Waterproof . . . . . . . . . . . . . . . . . . . . . . . floatable, waterproof down to 5 m / 16.4 ft
Battery . . . . . . . . . . . . . . . . . . . . . . . . . 1x CR2 / 3 V
Compass
Compass . . . . . . . . . . . . . . . . . . . . . . . . digital, fully integrated
Unit of measurement. . . . . . . . . . . . . . . . . . degrees
Display . . . . . . . . . . . . . . . . . . . . . . . . . 8 geographic directions
Range . . . . . . . . . . . . . . . . . . . . . . . . . 0° to 359°
Resolution value . . . . . . . . . . . . . . . . . . . . 1°
Accuracy . . . . . . . . . . . . . . . . . . . . . . . . +/- 3° to -/+ 5°
Tilt compensation . . . . . . . . . . . . . . . . . . . +/- 60° inclination angle / +/- 45° lateral angle
58
Tilt sensor
Unit of measurement . . . . . . . . . . . . . . . . . degrees
Range . . . . . . . . . . . . . . . . . . . . . . . . . +/- 60°
Resolution value . . . . . . . . . . . . . . . . . . . . 1°
Barometer
Unit of measurement . . . . . . . . . . . . . . . . . hPa (Hektopascal = Millibar), inHg (inch of mercury) or
Range . . . . . . . . . . . . . . . . . . . . . . . . . 900~1100 hPa / 26.60~32.49 inHg / 676~825 mmHg
Resolution value . . . . . . . . . . . . . . . . . . . . 1 hPa / 0.01 inHg / 1 mmHg
Parameter update . . . . . . . . . . . . . . . . . . . 6x per hour (indication update every sec.)*
Graphic indicator. . . . . . . . . . . . . . . . . . . . current, last 2, 4, 6 and 8 hours as graphic bar diagram
Log indicator . . . . . . . . . . . . . . . . . . . . . . previous 2, 4, 6 or 8 hours
Altimeter
Unit of measurement. . . . . . . . . . . . . . . . . . meters (m) or feet (ft)
Range . . . . . . . . . . . . . . . . . . . . . . . . . 0~ 9.000 m / 0~30.000 ft
Resolution value:. . . . . . . . . . . . . . . . . . . . 1 m / 3 ft
Parameter update . . . . . . . . . . . . . . . . . . . 6x per hour (indication update every sec.)*
mmHg (Torr)
59