BML SF2-I2 _ _ -A/QZ _ _ - Z _ _ 5-...
Incremental magnetic encoder system
9
Type code
9.1
Analog type code (BML SF2-...-A...)
S
= Sensor head
Construction:
F2
Pole width:
2
= 2 mm
Reference signal:
0
= No signal
1
= Single signal (or fixed-periodic)
2
= Pole-periodic signal
Alignment:
1
= Longitudinal
2
= Transverse
Interface:
A
= Analog Sin/Cos (1 V
Supply voltage:
5
= 5 V DC
Electrical connection:
KA_ _ =
PUR, shielded, standard, possible cable lengths 2, 5, 10, 15, 20 m (KA05 = 5 m cable)
KD_ _ =
PUR, shielded, for drag chain, possible cable lengths 2, 5, 10, 15, 20 m (KD05 = 5 m cable)
KF_ _ =
PUR, shielded, for fixed routing, possible cable lengths 2, 5, 10, 15, 20 m (KF05 = 5 m cable)
KA00,3-S284 = PUR, shielded, 0.3 m cable length, with M12 plug
28
english
)
PP
BML - SF2 - I201 - AZZZ - ZZZ5 - KA05