TROUBLE SHOOTING

Issue - COLD FLUID:
IF THE SMARTWASHER IS LOW ON FLUID, THE
HEATER AUTOMATICALLY SHUTS OFF.
Check to see if the "Add Fluid" indicators
are lit (there should be approximately 13"
(33 cm) of fluid in the machine).
If the "Add Fluid" light is lit, add a full
container of OzzyJuice (the light should go
out).
Allow for a reasonable warm up period and
then recheck.
The Thermostat is factory-set to maintain the fluid at 108° F or 115° F (+-2°)
Issue - FLUID SPILLAGE ONTO
FLOOR
OzzyJuice will cause the floor to become
slippery. Use caution when walking in or
near spilled fluid. To clean up an accidental
spill of new, unused fluid simply soak up
the solution with an absorbent material, (or
wash spillage down the nearest sanitary
sewer). If the spilled OzzyJuice has been
used, you must dispose of the spillage in
accordance with local regulations. If left to
dry, the fluid will leave a tacky spot on the
floor that when wet, will again become
slippery.
ChemFree Technical Support : 800-521-7182 www.chemfree.com
Issue - OVERHEATED FLUID
If the fluid becomes extremely hot and
exceeds
SmartWasher and replace the probe.
( 42°C or 46°C(+-1°)).
Issue - FLUID DISCOLORATION
OzzyJuice may become dark in color due
to dyes in oils or greases removed from
dirty parts. This will not affect its cleaning
power. If the fluid should develop a strong
odor, it may be contaminated and you
should call ChemFree Technical Support
for assistance in diagnosing the problem.