INFLATION SYSTEM
UML PRO SENSOR AUTOMATIC INFLATION SYSTEM
This professional lifejacket Inflator supports both manual and automatic inflation facilities,
featuring one focal point of status indication, confirming if the unit has been automatically or
manually activated and CO2 cylinder status.
The indication system on the Pro Sensor® Automatic Inflator allows the user to establish if the
system has been fired including the added benefit of quickly identifying if a pierced CO2 cylinder
is accidentally refitted to the inflator during the servicing procedure.
The Pro Sensor® Automatic Inflator indication is only fully operational when both green
indicators are fully showing and water is not restricted to the Cartridge Firing Mechanism.
The CO2 cylinder must be checked each time you don your lifejacket to ensure it is tightly
screwed in by hand. In addition the cartridge must be checked to ensure it has not passed the
replace by date and is also fully screwed on tightly by hand.
The top indicator identifies the CO2 cylinder status. Red indicates it is missing or has been
pierced. Partially red indicates the CO2 cylinder is not screwed in fully or has been partially
pierced.
REMOVE THE CYLINDER AND ENSURE IT IS FULL AND HAS NOT BEEN PIERCED
BEFORE SCREWING BACK IN HAND TIGHT.
The bottom indication identifies the Automatic Firing Mechanism status. Red indicates it is
missing or has been activated. Partially red indicates the Automatic Firing Mechanism is not
screwed on fully.
BOTH INDICATIONS MUST BE FULLY SHOWING GREEN, THE CARTRIDGE WITHIN ITS
PRINTED REPLACE BY DATE AND WITH A FULL CO2 CYLINDER SCREWED IN HAND
TIGHT FOR CORRECT OPERATION.