If the earth terminal of the Vega 900 PSU is connected to the main incoming earth conductor of the end equipment,
the installer must cover the earth symbol with a label bearing the earth symbol of IEC60417-5019.
Note: All output voltages/variants may not be available as standard units, refer to datasheet for standard
product range. These (and other variants) may be available as non-standard or custom units, please contact
our sales team for details.

PRODUCTS COVERED

Unit Configuration Code:
V9 or Vega 900 range
where V9 = Vega 900 Range
followed by: C, D, F, or Q
where C = Customer air
D† = Ruggedised fan, forward airflow
F = Standard fan, forward airflow
Q = Quiet fan, forward airflow
† These fans must not be used for user accessible applications.
optionally followed by: F, I or S
where F = Fast-on or quick connect input terminals
S = Screw input terminals
I = IEC input
followed by: S, M, L, R, or T
where S = Standard Leakage (Class B Filter)
M = Medium Leakage
G = Moderate Leakage
L = Low Leakage
R = Reduced Leakage
T = Tiny Leakage
optionally followed by: E, F, EV, FV, EY, FY, xEW or xFW
where E = AC fail with PSU & fan enable and 5V aux supply
F = AC fail with PSU & fan inhibit and 5V aux supply
EV = AC fail with PSU & fan enable and 5V/300mA aux supply
FV = AC fail with PSU & fan inhibit and 5V/300mA aux supply
EY = AC fail with PSU & fan enable, 5V/300mA aux supply and fan fail signal
FY = AC fail with PSU & fan inhibit, 5V/300mA aux supply and fan fail signal
xEW = AC fail with PSU & fan enable and 5-15V/1A aux supply, where x = voltage setting
xFW = AC fail with PSU & fan inhibit and 5-15V/1A aux supply, where x = voltage setting
D = Primary digital option. Provides PSU inhibit and enable, fan monitor, standby supply, hours of
operation, serial numbers, mains fail, over temperature warning. When secondary digital options
fitted also provides status bytes, unit and module IDs, grouping, digital voltage and current limit
programming, secondary inhibit and enable, secondary turn on delay, global and secondary module
good, module monitoring.
Modules:
B@, C@, C1Y, D@, E@, F1, F2, H@/@ or @_@, L@, W2, W5 & W8.
where the letter represents a module and @ is a number between 1 and 5, which represents the number of
turns on the transformer secondary. By reference to the following table, this in turn defines the permitted
voltage range of the module.
Page 15 of 34
17155 issue 26, Sept 2019