NV700 Handbook
PRODUCTS COVERED
Unit Configuration Code:
NV-700 or NV7 (these models are identical)
followed by: S or C or U, where
Option Letter
S
Forward airflow, standard fan
C
Customer air, fan not fitted
U
Customer air, fan not fitted, cover not fitted
followed by: S or I, where
Option Letter
S
Screw input terminals
I
IEC input
followed by: S, M, L, R, or T, where
Option Letter
S
Standard Leakage (Class B Filter)
M
Medium Leakage
L
Low Leakage
R
Reduced Leakage
T
Tiny Leakage
Optionally followed by: EN#V, EN12V, EN13.5V, IN#V, IN12V, IN13.5V, ES#V, ES12V, ES13.5V, IS#V, IS12V or
IS13.5V, where
Option Letter
EN#V
AC good, global module good, PSU enable, 5-5.5V, 2A standby output
EN12V
AC good, global module good, PSU enable, 12V, 1A standby output
EN13.5V
AC good, global module good, PSU enable, 13.5V, 1A standby output
IN#V
AC good, global module good, PSU inhibit, 5-5.5V, 2A standby output
IN12V
AC good, global module good, PSU inhibit, 12V, 1A standby output
IN13.5V
AC good, global module good, PSU inhibit, 13.5V, 1A standby output
ES#V
AC good, PSU enable, 5-5.5V, 2A standby output
ES12V
AC good, PSU enable, 12V, 1A standby output
ES13.5V
AC good, PSU enable, 13.5V, 1A standby output
IS#V
AC good, PSU inhibit, 5-5.5V, 2A standby output
IS12V
AC good, PSU inhibit, 12V, 1A standby output
IS13.5V
AC good, PSU inhibit, 13.5V, 1A standby output
Where: # represents the standby output voltage and is in the range 5 to 5.5.
The Global Options Inhibit and Enable functions permit the customer to turn off or on the main psu outputs and the
fan. The standby supply is for use by the customer and provides an SELV output that continues to operate when all
the main psu outputs have been turned off using the Inhibit or Enable functions. All the functions of the Global
Option pass through a single 8 way PWB socket and are all rated SELV.
Modules:
Up to 4 of the following modules types may be fitted:
@B
@C
@CM
@BH
where @ is the output voltage of the module and is within the range given in the single output module table.
or
@/#DB or @_#DB
Airflow Option
Input Option
Leakage Option
Global Option
Page 15 of 30
17187 issue 19, October 2018