Venting The Cartridge Tank - Dometic Saneo B Instrucciones De Montaje

Ocultar thumbs Ver también para Saneo B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59
Saneo B, Saneo C
➤ Perform a leak test.
A
NOTICE!
The operating pressure (water pressure) of the solenoid valve should not
exceed 6 bar.
The solenoid valve is damaged by excessive pressure.
Performing a measurement to test the flushing output
I
NOTE
Water supply (vehicle-side pump):
The toilet requires a min. of 7 l/min provided by the vehicle at the outlet
of the hose connection of the toilet in order to ensure satisfactory flush-
ing output of 5 l/min.
For performing a measurement to test the flushing output, there are two variants:
Variant 1:
➤ Disconnect the hose connection of the toilet from the vehicle line.
➤ Place the open end of the line into a bucket.
➤ Actuate the flushing for 1 minute using the toilet operating unit.
➤ Measure the volume of water in the bucket.
The volume of water that is in the bucket corresponds to the water flow rate in
l/min.
Variant 2:
➤ Disconnect the hose connection of the toilet from the vehicle line.
➤ Connect a Gardena water meter to the toilet water line.
➤ Actuate the flushing using the toilet operating unit.
➤ Read the water flow in l/min on the Gardena water meter.
5.7

Venting the cartridge tank

Variant 1:
➤ In the niche floor, create an opening with a diameter of approx. 12 mm (fig. k,
page 16).
➤ Run the vent hose into this opening for discharge to the outside.
EN
Installing the toilet
29

Publicidad

Tabla de contenido
loading

Tabla de contenido