Technical Data - Dometic Saneo B Instrucciones De Montaje

Ocultar thumbs Ver también para Saneo B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59

Technical data

Pos./cable colour Label
A
B
C
D
wt
rt
bl
7
Technical data
:
Input voltage
Current consumption
:
Max. person weight
:
Dimensions
Operating temperature
:
Capacity
:
Test mark
I
NOTE
Water supply (vehicle-side pump):
The toilet requires a min. of 7 l/min provided by the vehicle at the outlet
of the hose connection of the toilet in order to ensure satisfactory flush-
ing output of 5 l/min.
32
Saneo B, BS, BLP, C, CS, CLP
(do not use when using a pressurised water pump)
Saneo BW, CW
Saneo B, BS, BLP, C, CS, CLP with pressurised water pump
(Australia)
Saneo BW, CW (UK)
White cable, earth (–)
Red cable, input (+)
Blue cable, output (+)
Control line for an external pump
(do not use when using a pressurised water pump)
:
See fig. 4, page 5 to fig. 9, page 10
:
Dometic Saneo
12 Vg
Max. 2 A with internal pump
Max. 10 A with external pump
150 kg
0 °C to +50 °C
16 l (cassette tank)
7 l (freshwater tank, optional)
13
N1
Saneo B, Saneo C
ECE R 10
EN

Publicidad

Tabla de contenido
loading