4.4
Machine data menu
Select
from the Main menu:
•
Enter or check the value for pulses per
100 m.
•
Enter the working width (m).
4.4.1
Pulses per 100 m
Amatron+ BAG0055.0 08.07
The Machine data menu is used to:
•
check machine-specific data and/or settings before
commissioning
Fig. 33
•
The "Pulses per 100 m" calibration value is required by the
+
AMATRON
to determine:
ο
the actual operational speed [km/h].
ο
the worked area.
•
The "Pulses per 100 m" calibration value can be manually
entered into the AMATRON
•
If the value is not known, it must be established by way of a
calibration run.
•
Establish the precise calibration value for "Pulses per 100 m" by
way of a calibration run:
ο
before commissioning.
ο
when using a different tractor or after changing to different
sized tractor tyres.
ο
if there is a discrepancy between the measured and the
actual operational speed.
ο
if there is a discrepancy between the measured and the
actual worked area.
ο
with different ground conditions.
•
The "Pulses per 100 m" calibration value must be established
under the prevailing conditions in the field. If the tractor is to be
used with all-wheel drive switched on, it must also be switched
on when establishing the calibration value.
Commissioning
+
, if the precise value is known.
27