98
Power Clamp
6-2
7-3
Trouble shooting
Code C14
Balancer recalibration by the user.
If several measuring runs are necessary to balance
a wheel because balance weight size and position
have to be readjusted repeatedly, this is often due to
insuffi cient measurement accuracy.
—
Balance a wheel, setting the type as NORMAL,
with less than 5 grams per plane.
—
Check in "fi ne" mode.
—
Go into code C14.
"CAL 1" appears and the machine beeps.
—
Perform the wheel measuring run.
At the end the display shows "CAL 2".
Screw on the User Calibration Weight, as shown
—
in Figure 6-2.
—
Perform the wheel measuring run.
At the end the display appears as shown in
Figure 7-3 to indicate that calibration was performed
correctly.
Note: Any error (by the operator) closes the program.
Error codes are listed in Section 7.1.2.
Code C21
This code provides information about the program
version and the balancer model name
Go into code C21.
—
Information about the software version appears.
—
Press the "-" key to view the Kernel version.
The information is visible for as long as the key is
pressed.
—
Press the "+" key or the "FINE" key to view the
balancer model.
Note: The information is visible for as long as the
key is pressed.
* = Factory adjusted mode